A porous silicon biosensor based on P450 enzyme for arachidonic acid detection was developed. A new transduction method is presented with a simultaneous measurement of refractive index and fluorescence intensity changes when the analyte is binding to an enzyme on the porous silicon surface. A fluorophore bound to a cysteine residue in an allosteric position of the haem domain (BMP) of cytochrome P450 BM3 enhances its fluorescence intensity upon interaction with its substrate arachidonic acid, involved in diseases such as Alzheimer's, liver cancer and cellular inflammation processes. BMP has been anchored on porous silicon surface and the new transduction method has been successfully exploited to develop a biosensor for arachidonic acid, reaching a detection limit of 10. μM arachidonic acid in a dynamic range of 10-200. μM. Moreover, the change of the refractive index has been also monitored at the same time, displaying a higher detection limit of 30. μM. Preliminary test were also conducted in plasma proving the high specificity and selectivity of the sensor even in presence of interferents in the range of 50-100. μM. Here we suggest these two detection systems could be used simultaneously to increase the accuracy and the dynamic range of the sensor avoiding a false positive response.

P450-based porous silicon biosensor for arachidonic acid detection

FERRERO, VALENTINA;SADEGHI, JILA;GILARDI, Gianfranco
2011-01-01

Abstract

A porous silicon biosensor based on P450 enzyme for arachidonic acid detection was developed. A new transduction method is presented with a simultaneous measurement of refractive index and fluorescence intensity changes when the analyte is binding to an enzyme on the porous silicon surface. A fluorophore bound to a cysteine residue in an allosteric position of the haem domain (BMP) of cytochrome P450 BM3 enhances its fluorescence intensity upon interaction with its substrate arachidonic acid, involved in diseases such as Alzheimer's, liver cancer and cellular inflammation processes. BMP has been anchored on porous silicon surface and the new transduction method has been successfully exploited to develop a biosensor for arachidonic acid, reaching a detection limit of 10. μM arachidonic acid in a dynamic range of 10-200. μM. Moreover, the change of the refractive index has been also monitored at the same time, displaying a higher detection limit of 30. μM. Preliminary test were also conducted in plasma proving the high specificity and selectivity of the sensor even in presence of interferents in the range of 50-100. μM. Here we suggest these two detection systems could be used simultaneously to increase the accuracy and the dynamic range of the sensor avoiding a false positive response.
2011
28
320
325
Biosensor; Cytochrome P450; fluorescence
Giovannozzi; Ferrero; Pennecchi; Sadeghi; Gilardi; Rossi
File in questo prodotto:
File Dimensione Formato  
BIOS4642.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 895.33 kB
Formato Adobe PDF
895.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/129584
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact