Fast field-cycling (FFC) MRI allows switching of the magnetic field during an imaging scan. FFC-MRI takes advantage of the T 1 dispersion properties of contrast agents to improve contrast, thus enabling more sensitive detection of the agent. A new contrast agent designed specifically for use with FFC was imaged using both a homebuilt FFC-MRI system and a 3 T Philips clinical MRI scanner. T 1 dispersion curves were obtained using a commercial relaxometer which showed large changes in relaxation rate between fields. A model of magnetization behaviour was used to predict optimum evolution times for the maximum T 1 contrast between samples at each field. Images were processed and analysed to create maps of R1 values using a set of images at each field. The R 1 maps produced at two different fields were then subtracted from each other in order to create a map of ΔR 1 in which pixel values depend on the change in R 1 of the sample between the two fields. The dispersion properties of the agent resulted in higher contrast in a ΔR 1 image compared with a standard T 1-weighted image.

The use of contrast agents with fast field-cycling magnetic resonance imaging

BARONI, SIMONA;AIME, Silvio;
2011-01-01

Abstract

Fast field-cycling (FFC) MRI allows switching of the magnetic field during an imaging scan. FFC-MRI takes advantage of the T 1 dispersion properties of contrast agents to improve contrast, thus enabling more sensitive detection of the agent. A new contrast agent designed specifically for use with FFC was imaged using both a homebuilt FFC-MRI system and a 3 T Philips clinical MRI scanner. T 1 dispersion curves were obtained using a commercial relaxometer which showed large changes in relaxation rate between fields. A model of magnetization behaviour was used to predict optimum evolution times for the maximum T 1 contrast between samples at each field. Images were processed and analysed to create maps of R1 values using a set of images at each field. The R 1 maps produced at two different fields were then subtracted from each other in order to create a map of ΔR 1 in which pixel values depend on the change in R 1 of the sample between the two fields. The dispersion properties of the agent resulted in higher contrast in a ΔR 1 image compared with a standard T 1-weighted image.
2011
Inglese
Sì, ma tipo non specificato
56
105
115
11
REGNO UNITO DI GRAN BRETAGNA
262
5
Hógáin DO; Davies GR; Baroni S; Aime S; Lurie DJ
info:eu-repo/semantics/article
none
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/131218
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact