Biosensors are versatile tools for monitoring molecular interactions. Herein, we report a novel assay designed to detect anti-platelet-derived growth factor receptor α (PDGFRα) autoantibodies in the serum of patients affected by systemic sclerosis (SSc), an autoimmune disease of the connective tissue. The assay was based on resonant mirror sensing, and used recombinant PDGFRα as molecular “bait” for anti-PDGFRα autoantibodies (IgG class). The selection and optimization of the analytical procedure required a preliminary investigation on the preservation of the native-like conformation of the receptor following the immobilization procedure. The PDGFRα-based biosensor was used to test IgG purified from sera of SSc patients and healthy controls (HC). The specificity and the reversibility of the interaction permitted a rapid analysis, a single detection test requiring only a few minutes. Remarkably, this assay could discriminate between SSc patients and HC. This receptor-based biosensor, based on the reversible interaction between a blocked macromolecule and soluble ligands, and with major advantages such as the rapidity, the reusability of the capturing surface and the low cost per single test, could represent a promising approach for the diagnosis of SSc and other diseases characterized by anti-receptor autoantibodies or other bioactive ligands to cellular receptors.

Biosensor-based Binding Assay for Platelet-Derived Growth Factor Receptor-α Autoantibodies in Human Serum

NACCI, GIULIA;FUNARO, Ada;
2013-01-01

Abstract

Biosensors are versatile tools for monitoring molecular interactions. Herein, we report a novel assay designed to detect anti-platelet-derived growth factor receptor α (PDGFRα) autoantibodies in the serum of patients affected by systemic sclerosis (SSc), an autoimmune disease of the connective tissue. The assay was based on resonant mirror sensing, and used recombinant PDGFRα as molecular “bait” for anti-PDGFRα autoantibodies (IgG class). The selection and optimization of the analytical procedure required a preliminary investigation on the preservation of the native-like conformation of the receptor following the immobilization procedure. The PDGFRα-based biosensor was used to test IgG purified from sera of SSc patients and healthy controls (HC). The specificity and the reversibility of the interaction permitted a rapid analysis, a single detection test requiring only a few minutes. Remarkably, this assay could discriminate between SSc patients and HC. This receptor-based biosensor, based on the reversible interaction between a blocked macromolecule and soluble ligands, and with major advantages such as the rapidity, the reusability of the capturing surface and the low cost per single test, could represent a promising approach for the diagnosis of SSc and other diseases characterized by anti-receptor autoantibodies or other bioactive ligands to cellular receptors.
2013
S7
7
10
http://www.omicsonline.org/searchresult.php
Platelet-Derived Growth Factor Receptor; autoantibodies
M. Cuccioloni; G. Moroncini; M. Mozzicafreddo; K.N. Pozniak; G. Nacci; A. Grieco; C. Paolini; C. Tonnini; A. Funaro; M. Angeletti; A. Gabrielli
File in questo prodotto:
File Dimensione Formato  
1285022_pdf.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.64 MB
Formato Adobe PDF
1.64 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/142222
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact