Study Type - Therapy (case series) Level of Evidence 4 What's known on the subject? and What does the study add? New techniques and instrumentation in laparoscopy including the use of 'single-port' devices and natural orifice transluminal endoscopic surgery have been proposed to reduce the invasiveness of these procedures. The introduction of small laparoscopic instruments (<3 mm) continues to further the field. To date, mini-laparoscopic instruments have been used in many urological procedures, e.g. pyeloplasty in the paediatric population. However, data of pure mini-laparoscopic pyeloplasty (mLP) for the treatment of pelvi-ureteric junction obstruction in the adult population are lacking. In a selected adult population mLP is feasible and safe. Perioperative and 1-year functional results are comparable with those of standard LP, while cosmetic results of mLP are more appreciated by the patients. OBJECTIVE: To evaluate perioperative and cosmetic results after pure mini-laparoscopic pyeloplasty (mLP) compared with standard LP (sLP) in an adult population. PATIENTS AND METHODS: From April 2009 to June 2010, 12 patients underwent mLP for pelvi-ureteric junction (PUJ) obstruction (PUJO). For comparison, 24 patients that had previously undergone sLP were pooled from our institutional database. All patients were assessed preoperatively with physical examination, abdominal ultrasonography, intravenous urography or computed tomography and renal scintigraphy (RS). In all cases, an Anderson-Hynes transperitoneal approach was used. After surgery, cosmetic results were assessed using a Patient Scar Assessment Questionnaire (PSAQ), and RS measured reconstructive success at 1-year after LP. Demographic and perioperative variables were recorded. Groups were compared using chi-squared and Wilcoxon-Mann-Whitney tests (P < 0.05 was considered significant). RESULTS: Baseline characteristics were similar between the groups. There were no differences in operative duration or blood loss. One mLP required conversion to sLP due to minor bleeding. Analgesic consumption and the pain visual analogue scale scores were not significantly different between the sLP and mLP cohorts. The average postoperative hospital stay for the mLP group was significantly shorter than that for the sLP group (P = 0.024). Complication and success rates between the groups were not significantly different. PSAQ scores showed that mLP patients were significantly more satisfied with their cosmetic result. CONCLUSIONS: mLP appears to be safe, feasible and effective in the treatment of PUJOs. Cosmetically, mLP is better than sLP.

Standard vs mini-laparoscopic pyeloplasty: perioperative outcomes and cosmetic results

Fiori C.;Morra I;Bertolo R;MELE, FABRIZIO;PORPIGLIA, Francesco
2013-01-01

Abstract

Study Type - Therapy (case series) Level of Evidence 4 What's known on the subject? and What does the study add? New techniques and instrumentation in laparoscopy including the use of 'single-port' devices and natural orifice transluminal endoscopic surgery have been proposed to reduce the invasiveness of these procedures. The introduction of small laparoscopic instruments (<3 mm) continues to further the field. To date, mini-laparoscopic instruments have been used in many urological procedures, e.g. pyeloplasty in the paediatric population. However, data of pure mini-laparoscopic pyeloplasty (mLP) for the treatment of pelvi-ureteric junction obstruction in the adult population are lacking. In a selected adult population mLP is feasible and safe. Perioperative and 1-year functional results are comparable with those of standard LP, while cosmetic results of mLP are more appreciated by the patients. OBJECTIVE: To evaluate perioperative and cosmetic results after pure mini-laparoscopic pyeloplasty (mLP) compared with standard LP (sLP) in an adult population. PATIENTS AND METHODS: From April 2009 to June 2010, 12 patients underwent mLP for pelvi-ureteric junction (PUJ) obstruction (PUJO). For comparison, 24 patients that had previously undergone sLP were pooled from our institutional database. All patients were assessed preoperatively with physical examination, abdominal ultrasonography, intravenous urography or computed tomography and renal scintigraphy (RS). In all cases, an Anderson-Hynes transperitoneal approach was used. After surgery, cosmetic results were assessed using a Patient Scar Assessment Questionnaire (PSAQ), and RS measured reconstructive success at 1-year after LP. Demographic and perioperative variables were recorded. Groups were compared using chi-squared and Wilcoxon-Mann-Whitney tests (P < 0.05 was considered significant). RESULTS: Baseline characteristics were similar between the groups. There were no differences in operative duration or blood loss. One mLP required conversion to sLP due to minor bleeding. Analgesic consumption and the pain visual analogue scale scores were not significantly different between the sLP and mLP cohorts. The average postoperative hospital stay for the mLP group was significantly shorter than that for the sLP group (P = 0.024). Complication and success rates between the groups were not significantly different. PSAQ scores showed that mLP patients were significantly more satisfied with their cosmetic result. CONCLUSIONS: mLP appears to be safe, feasible and effective in the treatment of PUJOs. Cosmetically, mLP is better than sLP.
2013
111
3B
121
126
Mini-laparoscopic pyeloplasty; Cosmetic results
Fiori, Cristian; Morra, Irene; Bertolo, RICCARDO GIUSEPPE; Mele, Fabrizio; Chiarissi, Ml; Porpiglia, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/147350
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 29
social impact