Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients' clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; κ values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility.

Interobserver reliability in musculoskeletal ultrasonography: Results from a "Teach the Teachers" rheumatologist course

IAGNOCCO, Annamaria;
2006-01-01

Abstract

Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients' clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; κ values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility.
2006
65
1
14
19
http://www.scopus.com/inward/record.url?eid=2-s2.0-29144485638&partnerID=65&md5=d0ccc73a2905b7f569bb83cff708e71a
E. Naredo; I. Moller; C. Moragues; J.J. De Agustin; A.K. Scheel; W. Grassi; E. De Miguel; M. Backhaus; P. Balint; G.A.W. Bruyn; M.A. D'Agostino; E. Filippucci; Annamaria Iagnocco; D. Kane; J.M. Koski; L. Mayordomo; W.A. Schmidt; W.A.A. Swen; M. Szkudlarek; L. Terslev; S. Torp-Pedersen; J. Uson; R.J. Wakefield; C. Werner; Ultrasound Eular Working Group For Musculoskeletal
File in questo prodotto:
File Dimensione Formato  
177.pdf

Accesso aperto

Dimensione 132.31 kB
Formato Adobe PDF
132.31 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1613254
Citazioni
  • ???jsp.display-item.citation.pmc??? 45
  • Scopus 202
  • ???jsp.display-item.citation.isi??? 170
social impact