The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100 µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014–0.44 ng L−1) and excellent intra and inter-day precision (RSD% values in the range 1.8–4.4% and 2.7–5.7%, respectively) were achieved, with a total analysis time of 20 min per sample. A high number of samples – i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTPIN and WWTPOUT) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTPIN and WWTPOUT) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µg L−1.

Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ng L-1 determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples

BRUZZONITI, Maria Concetta;
2018-01-01

Abstract

The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100 µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014–0.44 ng L−1) and excellent intra and inter-day precision (RSD% values in the range 1.8–4.4% and 2.7–5.7%, respectively) were achieved, with a total analysis time of 20 min per sample. A high number of samples – i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTPIN and WWTPOUT) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTPIN and WWTPOUT) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µg L−1.
2018
176
412
421
Direct injection UHPLC-MS/MS; Drinking water; Environmental water; Matrix effect chemometrics; Perfluoroalkyl acids; Wastewater; Chemistry (all)
Ciofi, Lorenzo; Renai, Lapo; Rossini, Daniele; Ancillotti, Claudia; Falai, Alida; Fibbi, Donatella; Bruzzoniti, Maria Concetta; Santana rodriguez, Jose Juan; Orlandini, Serena; Del Bubba, Massimo
File in questo prodotto:
File Dimensione Formato  
Author's Copy.pdf

Accesso riservato

Descrizione: PDF Editoriale
Tipo di file: PDF EDITORIALE
Dimensione 737.17 kB
Formato Adobe PDF
737.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
4Open access.pdf

Open Access dal 17/08/2019

Descrizione: Articolo per open access
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 2.05 MB
Formato Adobe PDF
2.05 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1651878
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 29
social impact