Introduction. The impact on clinical outcomes of the metal coverage on the coronary surface (namely the metal-to-artery ratio) of currently used drug-eluting stents (DESs) has not been defined. Methods. All patients with a left main or bifurcation stenosis treated with percutaneous coronary intervention (PCI) using ultrathin stents (struts thinner than 81 μm) were enrolled with a prospective multicentre fashion. The rate of device-oriented endpoint [DOE, defined as a composite of target lesion revascularization (TLR) and stent thrombosis] was the primary endpoint, while its single components were the secondary ones, evaluated according to the metal-to-artery ratio. Results. After 14 ± 10.4 months 62 (7.5%) of 830 patients undergoing PCI on left main experienced a DOE without differences in the metal-to-artery ratio (14.5 ± 2.1 vs. 14.4 ± 1.9, P = 0.51). Fifty out (2.4%) of 2082 patients treated with PCI on a coronary bifurcation other than left main experienced a DOE, with a higher mean metal-to-artery ratio (15.3 ± 2.1 vs. 14.6 ± 2, P = 0.01). At multivariate analysis, together with hypertension and diabetes, the metal-to-artery ratio was an independent predictor of DOE (hazard ratio 1.7 : 1.02-1.34, P = 0.02) in nonleft main PCI. When analysed for diameter, we found a significant correlation with DOE when the stent diameter was inferior to 3.0 mm (hazard ratio 1.21: 1.06-1.38, P < 0.01, all 95% confidence interval); this result was mainly consistent for patients treated with provisional stenting. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less. Conclusion. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less.

Impact of the metal-to-artery ratio on clinical outcomes in left main and nonleft main bifurcation: insights the RAIN-CARDIOGROUP VII study (veRy thin stents for patients with left mAIn or bifurcatioN in real life)

Iannaccone, Mario
First
;
D'Ascenzo, Fabrizio;Cerrato, Enrico;De Ferrari, Gaetano Maria
Co-last
;
In corso di stampa

Abstract

Introduction. The impact on clinical outcomes of the metal coverage on the coronary surface (namely the metal-to-artery ratio) of currently used drug-eluting stents (DESs) has not been defined. Methods. All patients with a left main or bifurcation stenosis treated with percutaneous coronary intervention (PCI) using ultrathin stents (struts thinner than 81 μm) were enrolled with a prospective multicentre fashion. The rate of device-oriented endpoint [DOE, defined as a composite of target lesion revascularization (TLR) and stent thrombosis] was the primary endpoint, while its single components were the secondary ones, evaluated according to the metal-to-artery ratio. Results. After 14 ± 10.4 months 62 (7.5%) of 830 patients undergoing PCI on left main experienced a DOE without differences in the metal-to-artery ratio (14.5 ± 2.1 vs. 14.4 ± 1.9, P = 0.51). Fifty out (2.4%) of 2082 patients treated with PCI on a coronary bifurcation other than left main experienced a DOE, with a higher mean metal-to-artery ratio (15.3 ± 2.1 vs. 14.6 ± 2, P = 0.01). At multivariate analysis, together with hypertension and diabetes, the metal-to-artery ratio was an independent predictor of DOE (hazard ratio 1.7 : 1.02-1.34, P = 0.02) in nonleft main PCI. When analysed for diameter, we found a significant correlation with DOE when the stent diameter was inferior to 3.0 mm (hazard ratio 1.21: 1.06-1.38, P < 0.01, all 95% confidence interval); this result was mainly consistent for patients treated with provisional stenting. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less. Conclusion. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less.
In corso di stampa
Publish Ahead of Print
12
16
Iannaccone, Mario; D'Ascenzo, Fabrizio; Gatti, Paolo; Cerrato, Enrico; Nuñez-Gil, Ivan; Wojakowski, Wojciech; Capodanno, Davide; Figini, Filippo; Wańha, Wojciech; Chieffo, Alaide; De Ferrari, Gaetano Maria; Di Mario, Carlo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1743948
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact