A new solid-phase extraction (SPE) method has been developed and validated on a liquid chromatography (LC) coupled with a mass spectrometer for the determination of plasma concentrations of tenofovir (TNF) and emtricitabine (FTC) in HIV infected patients. Chromatographic separation was achieved with a gradient (acetonitrile and water with formic acid 0.05%) on an Atlantis 4.6 mm x 150 mm, reversed phase analytical column. Detection of TNF, FTC, and internal standard (IS) was achieved by electrospray ionization mass spectrometry (ESI-MS) in the positive ion mode. Calibration ranged from 15.6 to 4000 ng/mL for TNF and 11.7 to 3000 ng/mL for FTC. Plasma was analyzed, and the limit of quantitation was 15.6 ng/mL for TNF and 11.7 ng/mL for FTC; limit of detection was 2 ng/mL for TNF and 1.5 ng/mL for FTC. Mean recovery of TNF, FTC, and IS were 46.5% [relative standard deviation (RSD): 8.8%] and 88.8% (RSD: 1.0%), and 81.7% (RSD: 3.1%), respectively. The method did not show any significant interference with antiretrovirals or other concomitant drugs administered to patients, and no significant "matrix effects" were observed. The method was applied for the determination of antiretroviral plasma concentration of HIV-positive patients treated with FTC and/or TNF, in combination with various other antiretrovirals.

A new assay based on solid-phase extraction procedure with LC-MS to measure plasmatic concentrations of tenofovir and emtricitabine in HIV infected patients

D'AVOLIO, ANTONIO
First
;
SCIANDRA, Mauro;SICCARDI, MARCO;BAIETTO, LORENA;BONORA, Stefano;DI PERRI, Giovanni
Last
2008-01-01

Abstract

A new solid-phase extraction (SPE) method has been developed and validated on a liquid chromatography (LC) coupled with a mass spectrometer for the determination of plasma concentrations of tenofovir (TNF) and emtricitabine (FTC) in HIV infected patients. Chromatographic separation was achieved with a gradient (acetonitrile and water with formic acid 0.05%) on an Atlantis 4.6 mm x 150 mm, reversed phase analytical column. Detection of TNF, FTC, and internal standard (IS) was achieved by electrospray ionization mass spectrometry (ESI-MS) in the positive ion mode. Calibration ranged from 15.6 to 4000 ng/mL for TNF and 11.7 to 3000 ng/mL for FTC. Plasma was analyzed, and the limit of quantitation was 15.6 ng/mL for TNF and 11.7 ng/mL for FTC; limit of detection was 2 ng/mL for TNF and 1.5 ng/mL for FTC. Mean recovery of TNF, FTC, and IS were 46.5% [relative standard deviation (RSD): 8.8%] and 88.8% (RSD: 1.0%), and 81.7% (RSD: 3.1%), respectively. The method did not show any significant interference with antiretrovirals or other concomitant drugs administered to patients, and no significant "matrix effects" were observed. The method was applied for the determination of antiretroviral plasma concentration of HIV-positive patients treated with FTC and/or TNF, in combination with various other antiretrovirals.
2008
46
524
528
Antonio D'Avolio; Mauro Sciandra; Marco Siccardi; Lorena Baietto; Daniel Gonzalez de; Stefano Bonora; Giovanni Di Perri
File in questo prodotto:
File Dimensione Formato  
46-6-524.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 274.5 kB
Formato Adobe PDF
274.5 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/45179
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 34
social impact