COMPASS RICH-1 is a large size gaseous Cherenkov detector. Two reflecting spherical surfaces, covering a total area of about 21 m(2) hosted in the radiator vessel provide image focusing. The segmented surfaces are formed by 116 mirrors, with individual degrees of freedom for angular adjustment. An original method has been developed and applied for the on-line monitoring of the mirror alignment. Relative tilts between neighbouring mirror elements create discontinuities in the image of continuous lines reflected by the mirror wall. The measurement of the discontinuities can also provide information about the absolute tilt with a resolution of 0.1 mrad. An independent check and calibration of this method has been performed in laboratory using, as reference, a laser interferometer. We present the technical solutions adopted to implement the dedicated setup, the results of the method calibration by laser interferometer, and the preliminary results obtained measuring the alignment of the RICH-1 mirror wall. (C) 2008 Elsevier B.V. All rights reserved.

On-line mirror alignment monitoring method for COMPASS RICH-1

M. Alexeev;CHIOSSO, Michela;FERRERO, Andrea;ROCCO, Elena;
2008-01-01

Abstract

COMPASS RICH-1 is a large size gaseous Cherenkov detector. Two reflecting spherical surfaces, covering a total area of about 21 m(2) hosted in the radiator vessel provide image focusing. The segmented surfaces are formed by 116 mirrors, with individual degrees of freedom for angular adjustment. An original method has been developed and applied for the on-line monitoring of the mirror alignment. Relative tilts between neighbouring mirror elements create discontinuities in the image of continuous lines reflected by the mirror wall. The measurement of the discontinuities can also provide information about the absolute tilt with a resolution of 0.1 mrad. An independent check and calibration of this method has been performed in laboratory using, as reference, a laser interferometer. We present the technical solutions adopted to implement the dedicated setup, the results of the method calibration by laser interferometer, and the preliminary results obtained measuring the alignment of the RICH-1 mirror wall. (C) 2008 Elsevier B.V. All rights reserved.
2008
Inglese
595
194
196
2
262
31
M. Alexeev; R. Birsa; F. Bradamante; A. Bressan; M. Chiosso; P. Ciliberti; M. L. Colantoni; S. D. Torre; O. Denisov; V. Diaz; V. Duic; A. Ferrero; J. ...espandi
info:eu-repo/semantics/article
none
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/61256
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 11
social impact