A new method using high performance liquid chromatography coupled with electrospray mass spectrometry is described for the quantification of plasma concentration of tyrosine kinase inhibitors imatinib, dasatinib and nilotinib. A simple protein precipitation extraction procedure was applied on 250 microl of plasma aliquots. Chromatographic separation of drugs and Internal Standard (quinoxaline) was achieved with a gradient (acetonitrile and water + formic acid 0.05%) on a C18 reverse phase analytical column with 20min of analytical run, at flow rate of 1 ml/min. Mean intra-day and inter-day precision for all compounds were 4.3 and 11.4%; mean accuracy was 1.5%; extraction recovery ranged within 95 and 114%. Calibration curves ranged from 10,000 to 62.5 ng/ml. The limit of quantification was set at 78.1 ng/ml for imatinib and at 62.5 ng/ml for dasatinib and nilotinib. This novel developed methodology allows a specific, sensitive and reliable simultaneous determination of the three tyrosine kinase inhibitors imatinib, dasatinib and nilotinib in a single chromatographic run, useful for drugs estimation in plasma of patients affected by chronic myeloid leukemia.

New HPLC-MS method for the simultaneous quantification of the antileukemia drugs imatinib, dasatinib, and nilotinib in human plasma

DE FRANCIA, SILVIA
First
;
D'AVOLIO, ANTONIO;PIRRO, Elisa;BAIETTO, LORENA;SICCARDI, MARCO;SIMIELE, MARCO;RACCA, Silvia Anna;SAGLIO, Giuseppe;DI CARLO, Francesco;DI PERRI, Giovanni
Last
2009-01-01

Abstract

A new method using high performance liquid chromatography coupled with electrospray mass spectrometry is described for the quantification of plasma concentration of tyrosine kinase inhibitors imatinib, dasatinib and nilotinib. A simple protein precipitation extraction procedure was applied on 250 microl of plasma aliquots. Chromatographic separation of drugs and Internal Standard (quinoxaline) was achieved with a gradient (acetonitrile and water + formic acid 0.05%) on a C18 reverse phase analytical column with 20min of analytical run, at flow rate of 1 ml/min. Mean intra-day and inter-day precision for all compounds were 4.3 and 11.4%; mean accuracy was 1.5%; extraction recovery ranged within 95 and 114%. Calibration curves ranged from 10,000 to 62.5 ng/ml. The limit of quantification was set at 78.1 ng/ml for imatinib and at 62.5 ng/ml for dasatinib and nilotinib. This novel developed methodology allows a specific, sensitive and reliable simultaneous determination of the three tyrosine kinase inhibitors imatinib, dasatinib and nilotinib in a single chromatographic run, useful for drugs estimation in plasma of patients affected by chronic myeloid leukemia.
2009
877
1721
1726
Silvia De Francia; Antonio D'Avolio; Francesca De Martino; Elisa Pirro; Lorena Baietto; Marco Siccardi; Marco Simiele; Silvia Racca; Giuseppe Saglio; Francesco Di Carlo; Giovanni Di Perri
File in questo prodotto:
File Dimensione Formato  
Journal of Chromatography B.pdf

Accesso riservato

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 417.2 kB
Formato Adobe PDF
417.2 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/62705
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 104
  • ???jsp.display-item.citation.isi??? 86
social impact