Background: Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. Objective: To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Design, setting, and participants: Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. Intervention: All patients underwent a >= 10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). Measurements: PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Results and limitations: Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p <= 0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. Conclusions: In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and sufficient calibration. These novel nomograms represent robust tools and are thus generalizable to European men at risk of harboring PCa. Consequently, in presence of a PCA3 score, these nomograms may be safely used to assist clinicians when prostate biopsy is contemplated.

External Validation of Urinary PCA3-Based Nomograms to Individually Predict Prostate Biopsy Outcome

GONTERO, Paolo;
2010-01-01

Abstract

Background: Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. Objective: To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Design, setting, and participants: Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. Intervention: All patients underwent a >= 10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). Measurements: PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Results and limitations: Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p <= 0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. Conclusions: In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and sufficient calibration. These novel nomograms represent robust tools and are thus generalizable to European men at risk of harboring PCa. Consequently, in presence of a PCA3 score, these nomograms may be safely used to assist clinicians when prostate biopsy is contemplated.
2010
58
5
727
732
Prostate biopsy; Prostate cancer gene 3; Biomarker; Prostate cancer; Nomogram; External validation
Auprich M; Haese A; Walz J; Pummer K; de la Taille A; Graefen M; de Reijke T; Fisch M; Kil P; Gontero P; Irani J; Chun FK
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/84373
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 96
  • ???jsp.display-item.citation.isi??? 88
social impact