Periodic quality control (QC) for ultrasound scanners checks their overall performance, reducing the risk of inaccurate diagnoses. Data from routine annual QC activity were analyzed to optimize the scheduling and the criteria of further QC programs. Among all the ultrasound scanners (68 transducers) in use at the Regional Medical Department of the Aosta Valley, which are currently tested, 48.6% showed problems, mainly (35.3%) related to defects detectable by physical and mechanical inspection. Nearly two-thirds of these problems impacted QC parameters. Failures were significantly related to the workload and to the "technological level" of the equipment. QC scheduling should therefore include a daily/weekly physical inspection in addition to a more complete, objective and software algorithms-based test, the frequency of which should be tailored on the basis of the equipment characteristics.

Criteria and scheduling of quality control of B-mode and doppler ultrasonography equipment

BALBIS, SONIA MARIA;NUCERA, Daniele Michele;GUIOT, Caterina
2012-01-01

Abstract

Periodic quality control (QC) for ultrasound scanners checks their overall performance, reducing the risk of inaccurate diagnoses. Data from routine annual QC activity were analyzed to optimize the scheduling and the criteria of further QC programs. Among all the ultrasound scanners (68 transducers) in use at the Regional Medical Department of the Aosta Valley, which are currently tested, 48.6% showed problems, mainly (35.3%) related to defects detectable by physical and mechanical inspection. Nearly two-thirds of these problems impacted QC parameters. Failures were significantly related to the workload and to the "technological level" of the equipment. QC scheduling should therefore include a daily/weekly physical inspection in addition to a more complete, objective and software algorithms-based test, the frequency of which should be tailored on the basis of the equipment characteristics.
2012
40
3
167
173
http://onlinelibrary.wiley.com/doi/10.1002/jcu.v40.3/issuetoc
quality control; ultrasound equipment; Doppler; B-mode
S. Balbis; T. Meloni; S. Tofani; F. Zenone; D. Nucera; C. Guiot
File in questo prodotto:
File Dimensione Formato  
Balbis_et_al_2012.pdf

Accesso riservato

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 831.45 kB
Formato Adobe PDF
831.45 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/100726
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact