This paper reports the final results of an accurate and complete experimental study of the performance of a large-area (1150 × 566 mm2) planar drift chamber filled with a HeiC4H10 (70−30%) mixture. Sixteen chambers of this type will constitute the elements of the central part of the tracking device of FINUDA, one of the two spectrometers approved for running at DAΦNE. The measured spatial resolution across the full drift cell ranges from 80 to 120 μm for particles at normal incidence angle, and the measured spatial resolution along the sense wire, as measured by the charge division method, was better than 1% of the wire length. Efficiency, space-time relationship, long term stability and Lorentz angle were measured as well. Particular care was devoted to the study of the spatial resolution as a function of the incidence angle. The conclusion of this study is that the chamber performances are the same or better than those obtained with Ar-based mixtures.

Final results of an experimental study of a large-area planar drift chamber filled with a He-based mixture

BOTTA, Elena;BRESSANI, Tullio;BUSSO, Luigi;MARCELLO, Simonetta;
1997-01-01

Abstract

This paper reports the final results of an accurate and complete experimental study of the performance of a large-area (1150 × 566 mm2) planar drift chamber filled with a HeiC4H10 (70−30%) mixture. Sixteen chambers of this type will constitute the elements of the central part of the tracking device of FINUDA, one of the two spectrometers approved for running at DAΦNE. The measured spatial resolution across the full drift cell ranges from 80 to 120 μm for particles at normal incidence angle, and the measured spatial resolution along the sense wire, as measured by the charge division method, was better than 1% of the wire length. Efficiency, space-time relationship, long term stability and Lorentz angle were measured as well. Particular care was devoted to the study of the spatial resolution as a function of the incidence angle. The conclusion of this study is that the chamber performances are the same or better than those obtained with Ar-based mixtures.
1997
385
58
68
M. Agnello;P. A. Amaudruz;E. Botta;T. Bressani;L. Busso;D. Calvo;P. Cerello;C. Fanara;A. Feliciello;A. Filippi;F. Iazzi;S. Marcello;B. Minetti;N. Mirfakhrai;O. Morra;A. Raimondo;E. Rossetto;A. Sharma;A. Zenoni
File in questo prodotto:
File Dimensione Formato  
NIMA_385_1997_58.pdf

Accesso riservato

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.12 MB
Formato Adobe PDF
1.12 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/109820
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 16
social impact