The aim of this research was to analyze the influence of the position of the skull during cone-beam computed tomography (CBCT) scan and if the three-dimensional cephalometric measurements are influenced by skull orientation during CBCT scan.The study consisted of 5 CBCT scanning (KODAK 9500 Cone Beam 3D System unit) in 5 different positions of a dry skull. The data were imported in SIMPLANT OMS Software version 13.0. Fifteen three-dimensional cephalometric measurements were calculated; moreover, the mean, the SD, the maximum/minimum Δ, and the maximum/minimum Δ percentage were calculated. The statistical analysis was performed by an independent-samples t-test to evaluate differences between the 5 scans.No difference was found in all the three-dimensional analysis. Twelve of 15 measurements have a Δ greater than 1.5, and 7 of 15 measurements have a Δ greater than 2. Nine of 15 have a Δ percentage greater than 5%. The preliminary results suggest that the three-dimensional cephalometric analysis is influenced by patient scanning position.
Cone Beam computed tomography: accuracy of 3D cephalometry analysis and influence of patient scanning position.
FRONGIA, GIANLUIGI;PIANCINO, MARIA GRAZIA;BRACCO, Pietro
2012-01-01
Abstract
The aim of this research was to analyze the influence of the position of the skull during cone-beam computed tomography (CBCT) scan and if the three-dimensional cephalometric measurements are influenced by skull orientation during CBCT scan.The study consisted of 5 CBCT scanning (KODAK 9500 Cone Beam 3D System unit) in 5 different positions of a dry skull. The data were imported in SIMPLANT OMS Software version 13.0. Fifteen three-dimensional cephalometric measurements were calculated; moreover, the mean, the SD, the maximum/minimum Δ, and the maximum/minimum Δ percentage were calculated. The statistical analysis was performed by an independent-samples t-test to evaluate differences between the 5 scans.No difference was found in all the three-dimensional analysis. Twelve of 15 measurements have a Δ greater than 1.5, and 7 of 15 measurements have a Δ greater than 2. Nine of 15 have a Δ percentage greater than 5%. The preliminary results suggest that the three-dimensional cephalometric analysis is influenced by patient scanning position.File | Dimensione | Formato | |
---|---|---|---|
JCraniofacSurg2012.pdf
Accesso riservato
Descrizione: Articolo principale
Tipo di file:
PDF EDITORIALE
Dimensione
370.62 kB
Formato
Adobe PDF
|
370.62 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.