PURPOSE: The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of (18)F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). METHODS: A comprehensive computer literature search of studies published through 30 June 2011 regarding (18)F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of (18)F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of (18)F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. RESULTS: Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of (18)F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of (18)F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of (18)F-DOPA PET or PET/CT was found. A significant increase in sensitivity of (18)F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. CONCLUSION: In patients with suspected PG (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. (18)F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind. Furthermore, SDHB gene mutations could influence (18)F-DOPA PET or PET/CT diagnostic performance.
Diagnostic performance of (18)F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis
GUALANO, MARIA ROSARIA;
2012-01-01
Abstract
PURPOSE: The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of (18)F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). METHODS: A comprehensive computer literature search of studies published through 30 June 2011 regarding (18)F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of (18)F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of (18)F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. RESULTS: Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of (18)F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of (18)F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of (18)F-DOPA PET or PET/CT was found. A significant increase in sensitivity of (18)F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. CONCLUSION: In patients with suspected PG (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. (18)F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind. Furthermore, SDHB gene mutations could influence (18)F-DOPA PET or PET/CT diagnostic performance.File | Dimensione | Formato | |
---|---|---|---|
treglia et al._129989.pdf
Accesso aperto
Descrizione: Articolo principale
Tipo di file:
PREPRINT (PRIMA BOZZA)
Dimensione
200.86 kB
Formato
Adobe PDF
|
200.86 kB | Adobe PDF | Visualizza/Apri |
Diagnostic_performance.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
486.94 kB
Formato
Adobe PDF
|
486.94 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.