Objective—To evaluate reproducibility of ejection fraction (EF), myocardial perfusion (MP), and pulmonary transit time (PTT) measured in a group of dogs by use of contrast echocardiography and to examine safety of this method by evaluating cardiac troponin I concentrations. Animals—6 healthy dogs. Procedures—2 bolus injections and a constant rate infusion of contrast agent were administered IV. Echocardiographic EF was determined by use of the area-length method and was calculated without and with contrast agent. The PTT and normalized PTT (PTT/mean R-R interval) were measured for each bolus. Constant rate infusion was used for global MP evaluation, and regional MP was calculated by use of a real-time method in 4 regions of interest of the left ventricle. Cardiac troponin I concentration was analyzed before and after contrast agent administration. Intraoberserver and interobserver variability was calculated. Results—EF was easier to determine with the ultrasonographic contrast agent. For the first and second bolus, mean ± SD PTT was 1.8 ± 0.2 seconds and 2.1 ± 0.3 seconds and normalized PTT was 3.4 ± 0.3 seconds and 3.5 ± 0.3 seconds, respectively. A coefficient of variation < 15% was obtained for global MP but not for the regional MPs. No differences were detected between precontrast and postcontrast cardiac troponin I concentrations. Conclusions and Clinical Relevance—Contrast echocardiography appeared to be a repeatable and safe technique for use in the evaluation of global MP and PTT in healthy dogs, and it improved delineation of the endocardial border in dogs.

Use of contrast echocardiography for quantitative and qualitative evaluation of myocardial perfusion and pulmonary transit time in healthy dogs.

TARDUCCI, Alberto;
2012-01-01

Abstract

Objective—To evaluate reproducibility of ejection fraction (EF), myocardial perfusion (MP), and pulmonary transit time (PTT) measured in a group of dogs by use of contrast echocardiography and to examine safety of this method by evaluating cardiac troponin I concentrations. Animals—6 healthy dogs. Procedures—2 bolus injections and a constant rate infusion of contrast agent were administered IV. Echocardiographic EF was determined by use of the area-length method and was calculated without and with contrast agent. The PTT and normalized PTT (PTT/mean R-R interval) were measured for each bolus. Constant rate infusion was used for global MP evaluation, and regional MP was calculated by use of a real-time method in 4 regions of interest of the left ventricle. Cardiac troponin I concentration was analyzed before and after contrast agent administration. Intraoberserver and interobserver variability was calculated. Results—EF was easier to determine with the ultrasonographic contrast agent. For the first and second bolus, mean ± SD PTT was 1.8 ± 0.2 seconds and 2.1 ± 0.3 seconds and normalized PTT was 3.4 ± 0.3 seconds and 3.5 ± 0.3 seconds, respectively. A coefficient of variation < 15% was obtained for global MP but not for the regional MPs. No differences were detected between precontrast and postcontrast cardiac troponin I concentrations. Conclusions and Clinical Relevance—Contrast echocardiography appeared to be a repeatable and safe technique for use in the evaluation of global MP and PTT in healthy dogs, and it improved delineation of the endocardial border in dogs.
2012
73
2
194
201
Cardiology; Cardiovascular; Echocardiography; pulmonary transit time; dog
S. Crosara; I. Ljungvall; M.L. Margiocco; J. Häggström; A. Tarducci; M. Borgarelli
File in questo prodotto:
File Dimensione Formato  
702939.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 669.34 kB
Formato Adobe PDF
669.34 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/131225
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact