Development and validation of simple, rapid, and reliable high-performance liquid chromatography (HPLC)-UV method for quantification of major tyrosine kinase inhibitors, imatinib, dasatinib, and nilotinib, in human plasma is presented. Chromatographic separation of the drugs is achieved on an RP-C(18) column at flow rate of 0.9 mL/min at 35°C; eluate is monitored at 267 nm. Mean intra-day and inter-day precision for all compounds are 2.5 and 13.3%; mean accuracy is 13.9%; extraction recovery ranges within 40.24 and 81.81%. Calibration curves range from 10 to 0.005 μg/mL. Limits of detection are 10 ng/mL for imatinib and nilotinib, 50 ng/mL for dasatinib; limits of quantitation are 50 ng/mL for imatinib and nilotinib, 100 ng/mL for dasatinib. Although this method allows the detection of dasatinib, levels found in patients plasma are close to the limit of detection, then below the limit of quantitation. Quantification with HPLC-mass spectrometry, then, is required for dasatinib to give a correct evaluation. In conclusion, the sensitivity of this new method is sufficient to perform therapeutic monitoring and pharmacokinetic studies of imatinib and nilotinib but not dasatinib in CML patients.

A new HPLC-UV validated method for therapeutic drug monitoring of tyrosine kinase inhibitors in leukemic patients.

PIRRO, Elisa;DE FRANCIA, SILVIA;FAVA, Carmen;RACCA, Silvia Anna;SAGLIO, Giuseppe;DI CARLO, Francesco
2011-01-01

Abstract

Development and validation of simple, rapid, and reliable high-performance liquid chromatography (HPLC)-UV method for quantification of major tyrosine kinase inhibitors, imatinib, dasatinib, and nilotinib, in human plasma is presented. Chromatographic separation of the drugs is achieved on an RP-C(18) column at flow rate of 0.9 mL/min at 35°C; eluate is monitored at 267 nm. Mean intra-day and inter-day precision for all compounds are 2.5 and 13.3%; mean accuracy is 13.9%; extraction recovery ranges within 40.24 and 81.81%. Calibration curves range from 10 to 0.005 μg/mL. Limits of detection are 10 ng/mL for imatinib and nilotinib, 50 ng/mL for dasatinib; limits of quantitation are 50 ng/mL for imatinib and nilotinib, 100 ng/mL for dasatinib. Although this method allows the detection of dasatinib, levels found in patients plasma are close to the limit of detection, then below the limit of quantitation. Quantification with HPLC-mass spectrometry, then, is required for dasatinib to give a correct evaluation. In conclusion, the sensitivity of this new method is sufficient to perform therapeutic monitoring and pharmacokinetic studies of imatinib and nilotinib but not dasatinib in CML patients.
2011
49
10
753
757
http://chromsci.oxfordjournals.org/content/49/10/753.long
Antineoplastic Agents; Benzamides; Chromatography, High Pressure Liquid; Dasatinib; Drug Monitoring; Humans; Imatinib Mesylate; Leukemia, Myelogenous, Chronic, BCR-ABL Positive; Linear Models; Piperazines; Protein-Tyrosine Kinases; Pyrimidines; Reproducibility of Results; Sensitivity and Specificity; Thiazoles
Pirro E; De Francia S; De Martino F; Fava C; Ulisciani S; Cambrin GR; Racca S; Saglio G; Di Carlo F
File in questo prodotto:
File Dimensione Formato  
Post print Pirro E. J Chromatogr Sci.pdf

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 783.01 kB
Formato Adobe PDF
783.01 kB Adobe PDF Visualizza/Apri
Pirro JCS pdf.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 491.7 kB
Formato Adobe PDF
491.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/133436
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 39
social impact