OBJECTIVES: To determine sensitivity and specificity of P wave duration in the identification of left atrial enlargement in dogs. METHODS: Electrocardiograms from normal dogs and dogs with various cardiovascular diseases were evaluated. Inclusion criteria were the availability of an electrocardiogram showing a stable isoelectric line, easily recognizable P waves and good quality two-dimensional echocardiographic estimate of left atrial dimensions using the left atrial to aortic root ratio. Using a metal caliper system, P wave duration was measured to the nearest 10 milliseconds for six consecutive heart beats; data were then averaged for each dog. The accuracy of P wave duration in predicting left atrial enlargement was determined using a receiver operating characteristic analysis. RESULTS: One hundred and fifty-six dogs were included in the study. Average P wave durations of 20, 30, 40 and 50 milliseconds yielded sensitivities of 100, 85, 68 and 40% and specificities of 0, 16, 64 and 93%, respectively, for the diagnosis of Left Atrial Enlargement by echocardiography. The estimated area under curve of the receiver operating characteristic curve was 0·70 (95% confidence interval: 0·60 to 0·80). CLINICAL SIGNIFICANCE: The diagnostic performance of P wave duration for identification of left atrial enlargement in dogs presents considerable limitations.

Diagnostic performance of P wave duration in the identification of left atrial enlargement in dogs.

P. Savarino;TARDUCCI, Alberto;
2012-01-01

Abstract

OBJECTIVES: To determine sensitivity and specificity of P wave duration in the identification of left atrial enlargement in dogs. METHODS: Electrocardiograms from normal dogs and dogs with various cardiovascular diseases were evaluated. Inclusion criteria were the availability of an electrocardiogram showing a stable isoelectric line, easily recognizable P waves and good quality two-dimensional echocardiographic estimate of left atrial dimensions using the left atrial to aortic root ratio. Using a metal caliper system, P wave duration was measured to the nearest 10 milliseconds for six consecutive heart beats; data were then averaged for each dog. The accuracy of P wave duration in predicting left atrial enlargement was determined using a receiver operating characteristic analysis. RESULTS: One hundred and fifty-six dogs were included in the study. Average P wave durations of 20, 30, 40 and 50 milliseconds yielded sensitivities of 100, 85, 68 and 40% and specificities of 0, 16, 64 and 93%, respectively, for the diagnosis of Left Atrial Enlargement by echocardiography. The estimated area under curve of the receiver operating characteristic curve was 0·70 (95% confidence interval: 0·60 to 0·80). CLINICAL SIGNIFICANCE: The diagnostic performance of P wave duration for identification of left atrial enlargement in dogs presents considerable limitations.
2012
53
5
267
272
electrocardiogram; dog; P wave
P. Savarino; M. Borgarelli; A. Tarducci; S. Crosara; N.M. Bello; M.L. Margiocco
File in questo prodotto:
File Dimensione Formato  
1162042.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 579.96 kB
Formato Adobe PDF
579.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
POST PRINT-Diagnostic performance of P wave duration in the identification of left atrial enlargement in dogs.pdf

Open Access dal 02/05/2013

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 478.59 kB
Formato Adobe PDF
478.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/133849
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact