We read with great interest the article by Neumann et al1 on the technique for removing the over-the-scope-clip (OTSC) in an ex vivo porcine model. As correctly stated, a potential indication for removal of an OTSC could be its misplacement. In this regard, it is reported that a second OTSC beside the first one is not always easy to deploy and could therefore be unsuccessful. By removing the first clip, one can realistically think that it is possible to correctly deploy a further clip.2 Our objection is in regard to the technique. The technique proposed seems in fact not always applicable (80% of the proposed series, even in an inanimate model) because of the need to visualize the oval hole of the clip. In any case, it seems relatively complex because only two thirds of the feasible cases resulted in success. Finally, the report raises some concerns about safety because retraction of the OTSC in a closed position suggests a realistic possibility that the tissue within the jaws could get entrapped and torn, reopening the closed defect. It is probably not well known that a characteristic of a superalloy such as nitinol is the change in stiffness at varying temperatures. Cooling nitinol below 10°C would result in an extremely weak force of the material, whatever shape still remains. At this low temperature, the material changes to its martensitic grid structure with no dimensional change but is then easily pseudo-plastic deformable, which means that one can easily change the shape while applying a low force. Application of heat again will cause the clip to automatically take up its original shape, generating the high force. Thanks to this precious characteristic, we were able to remove a misplaced OTSC in a human being with a large rectal chronic fistula (Fig. 1). As shown in the video (video 1), by submerging the clip for 1 minute with saline solution previously kept in the refrigerator at 4°C (Fig. 2), we could easily grasp a visible part of the clip frame with a conventional foreign body grasper (Fig. 3). The OTSC then offered minimal resistance, and once the previous site of deployment was inspected (Fig. 4), we could hardly see the signs of its presence by minimal tissue tears. The patient had an uneventful recovery. The technique is therefore very simple, and although we cannot demonstrate a series, we believe it is always reproducible. In fact, just after deployment, at least one part of the OTSC is always visible to be caught by a foreign body grasper. We believe this report may represent a useful message to all centers currently using the OTSC, and we hope it can be of some help in critical situations.

The way to remove an over-the-scope-clip (with video)

AREZZO, Alberto;MORINO, Mario
2013-01-01

Abstract

We read with great interest the article by Neumann et al1 on the technique for removing the over-the-scope-clip (OTSC) in an ex vivo porcine model. As correctly stated, a potential indication for removal of an OTSC could be its misplacement. In this regard, it is reported that a second OTSC beside the first one is not always easy to deploy and could therefore be unsuccessful. By removing the first clip, one can realistically think that it is possible to correctly deploy a further clip.2 Our objection is in regard to the technique. The technique proposed seems in fact not always applicable (80% of the proposed series, even in an inanimate model) because of the need to visualize the oval hole of the clip. In any case, it seems relatively complex because only two thirds of the feasible cases resulted in success. Finally, the report raises some concerns about safety because retraction of the OTSC in a closed position suggests a realistic possibility that the tissue within the jaws could get entrapped and torn, reopening the closed defect. It is probably not well known that a characteristic of a superalloy such as nitinol is the change in stiffness at varying temperatures. Cooling nitinol below 10°C would result in an extremely weak force of the material, whatever shape still remains. At this low temperature, the material changes to its martensitic grid structure with no dimensional change but is then easily pseudo-plastic deformable, which means that one can easily change the shape while applying a low force. Application of heat again will cause the clip to automatically take up its original shape, generating the high force. Thanks to this precious characteristic, we were able to remove a misplaced OTSC in a human being with a large rectal chronic fistula (Fig. 1). As shown in the video (video 1), by submerging the clip for 1 minute with saline solution previously kept in the refrigerator at 4°C (Fig. 2), we could easily grasp a visible part of the clip frame with a conventional foreign body grasper (Fig. 3). The OTSC then offered minimal resistance, and once the previous site of deployment was inspected (Fig. 4), we could hardly see the signs of its presence by minimal tissue tears. The patient had an uneventful recovery. The technique is therefore very simple, and although we cannot demonstrate a series, we believe it is always reproducible. In fact, just after deployment, at least one part of the OTSC is always visible to be caught by a foreign body grasper. We believe this report may represent a useful message to all centers currently using the OTSC, and we hope it can be of some help in critical situations.
2013
77
6
974
975
http://www.giejournal.org/article/S0016-5107(13)00091-6/fulltext
Alberto Arezzo;Alberto Bullano;Harald Fischer;Mario Morino
File in questo prodotto:
File Dimensione Formato  
the way to remove1-s2.0-S0016510713000916-main.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 489.14 kB
Formato Adobe PDF
489.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
The way to remove an over_4aperto.pdf

Open Access dal 01/10/2014

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 115.13 kB
Formato Adobe PDF
115.13 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/134536
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact