INTRODUCTION: Silent cerebral ischemic lesions have recently emerged as the most frequent complications after pulmonary vein isolation (PVI). To reduce thromboembolic complications, new types of catheters and energy source have been introduced in clinical practice. The study purpose is to compare the incidence of new silent cerebral ischemic events in patients with paroxysmal atrial fibrillation (PAF) undergoing PVI with different ablation technologies. METHODS AND RESULTS: One hundred and eight patients (67% men; age 56 ± 9 years) with PAF were enrolled in a consecutive manner to undergo PVI performed with irrigated radiofrequency (RF) catheter (Group 1, 36 patients), multielectrode catheter (PVAC) associated with duty-cycled RF generator (Group 2, 36 patients) and cryoballoon (Group 3, 36 patients). The protocol included a cerebral magnetic resonance imaging before and after the procedure. After PVI, the following patients showed new silent cerebral ischemic lesions at postprocedural cerebral MRI: 3 patients in Group 1 (8.3%), 14 patients in Group 2 (38.9%), 2 patients in Group 3 (5.6%). PVAC related to higher incidence of silent cerebral ischemic events compared to irrigated RF (P = 0.002) and cryoballoon (P = 0.001), whereas no statistical differences were found between irrigated RF catheter and cryoballoon groups (8.3% vs 5.6%, P = 0.5). At the multivariate analysis, the only independent predictor of new ischemic asymptomatic cerebral lesions after PVI was ablation performed with PVAC (OR 1.48 95% CI 1.19-1.62, P < 0.001). CONCLUSION: The incidence of silent cerebral lesions after PVI is different depending on technologies used: PVAC increases the risk of 1.48 times compared to irrigated RF and cryoballoon ablation. 

Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon.

GAITA, Fiorenzo;TOSO, ELISABETTA;BLANDINO, ALESSANDRO
2011-01-01

Abstract

INTRODUCTION: Silent cerebral ischemic lesions have recently emerged as the most frequent complications after pulmonary vein isolation (PVI). To reduce thromboembolic complications, new types of catheters and energy source have been introduced in clinical practice. The study purpose is to compare the incidence of new silent cerebral ischemic events in patients with paroxysmal atrial fibrillation (PAF) undergoing PVI with different ablation technologies. METHODS AND RESULTS: One hundred and eight patients (67% men; age 56 ± 9 years) with PAF were enrolled in a consecutive manner to undergo PVI performed with irrigated radiofrequency (RF) catheter (Group 1, 36 patients), multielectrode catheter (PVAC) associated with duty-cycled RF generator (Group 2, 36 patients) and cryoballoon (Group 3, 36 patients). The protocol included a cerebral magnetic resonance imaging before and after the procedure. After PVI, the following patients showed new silent cerebral ischemic lesions at postprocedural cerebral MRI: 3 patients in Group 1 (8.3%), 14 patients in Group 2 (38.9%), 2 patients in Group 3 (5.6%). PVAC related to higher incidence of silent cerebral ischemic events compared to irrigated RF (P = 0.002) and cryoballoon (P = 0.001), whereas no statistical differences were found between irrigated RF catheter and cryoballoon groups (8.3% vs 5.6%, P = 0.5). At the multivariate analysis, the only independent predictor of new ischemic asymptomatic cerebral lesions after PVI was ablation performed with PVAC (OR 1.48 95% CI 1.19-1.62, P < 0.001). CONCLUSION: The incidence of silent cerebral lesions after PVI is different depending on technologies used: PVAC increases the risk of 1.48 times compared to irrigated RF and cryoballoon ablation. 
2011
22
9
961
968
http://onlinelibrary.wiley.com/doi/10.1111/j.1540-8167.2011.02050.x/pdf
Gaita F;Leclercq JF;Schumacher B;Scaglione M;Toso E;Halimi F;Schade A;Froehner S;Ziegler V;Sergi D;Cesarani F;Blandino A
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/135649
Citazioni
  • ???jsp.display-item.citation.pmc??? 64
  • Scopus 253
  • ???jsp.display-item.citation.isi??? 195
social impact