The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.
NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study
ROSSI, Roberto;FERRO, Andrea;BRUZZONE, Matteo;BONASIA, Davide Edoardo;GARZARO, Giacomo;CASTOLDI, Filippo
2009-01-01
Abstract
The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.File | Dimensione | Formato | |
---|---|---|---|
8 LPS Chir Org Movim (1).pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
229.78 kB
Formato
Adobe PDF
|
229.78 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.