The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell. All patients were evaluated preoperatively, 3 and 6 months postoperatively, and annually thereafter using the Hospital for Special Surgery (HSS) knee score and the Knee Society Roentgenographic Evaluation System (KS-RES). Mean follow-up was 155.2±40.1 months (range, 78-240 months), with 32 patients examined at the final follow-up. All HSS knee scores increased from preoperatively to last follow-up. No statistically significance differences were found in the HSS knee scores between septic and aseptic revisions and between total or partial revisions. Progressive radiolucent lines were detected in 8 (25%) patients. Implant failure occurred in 11 (20.7%) patients; the cumulative survival of the implants was 80.4% at 150 months for the final 32 patients. The authors recommend use of this implant for revision total knee arthroplasty, especially in patients with severe instability and bone loss.

Endo-Modell Rotating-hinge Total Knee for Revision Total Knee Arthroplasty.

CROVA, Maurizio;MASSAZZA, Giuseppe
2013-01-01

Abstract

The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell. All patients were evaluated preoperatively, 3 and 6 months postoperatively, and annually thereafter using the Hospital for Special Surgery (HSS) knee score and the Knee Society Roentgenographic Evaluation System (KS-RES). Mean follow-up was 155.2±40.1 months (range, 78-240 months), with 32 patients examined at the final follow-up. All HSS knee scores increased from preoperatively to last follow-up. No statistically significance differences were found in the HSS knee scores between septic and aseptic revisions and between total or partial revisions. Progressive radiolucent lines were detected in 8 (25%) patients. Implant failure occurred in 11 (20.7%) patients; the cumulative survival of the implants was 80.4% at 150 months for the final 32 patients. The authors recommend use of this implant for revision total knee arthroplasty, especially in patients with severe instability and bone loss.
2013
36 (10)
10
e1299
e1306
Bistolfi A; Rosso F; Crova M; Massazza G
File in questo prodotto:
File Dimensione Formato  
Massazza _ID 1231971_Endo-Modell Rotating-hinge Total Knee for Revision Total Knee Arthroplasty.pdf

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 655.46 kB
Formato Adobe PDF
655.46 kB Adobe PDF Visualizza/Apri
accesso riservato.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 771.18 kB
Formato Adobe PDF
771.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/138394
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 12
social impact