The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at root s = 7TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb(-1). The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 mu m in the DTs, 40-150 mu m in the CSCs, and 0.8-1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.

The performance of the CMS muon detector in proton-proton collisions at root s=7 TeV at the LHC

V. Sola;AMAPANE, Nicola Carlo;ARGIRO', Stefano;CASASSO, STEFANO;COSTA, Marco;MIGLIORE, Ernesto;MONACO, Vincenzo;MUSICH, MARCO;OBERTINO, Maria Margherita;PELLICCIONI, Mario;PERONI, Cristiana;ROMERO, Alessandra;SACCHI, Roberto;SOLANO, Ada Maria;BELLAN, Riccardo;COVARELLI, Roberto;
2013-01-01

Abstract

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at root s = 7TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb(-1). The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 mu m in the DTs, 40-150 mu m in the CSCs, and 0.8-1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.
2013
Inglese
Esperti anonimi
8
P11002
-
105
http://arxiv.org/abs/1306.6905
GERMANIA
4 – prodotto già presente in altro archivio Open Access (arXiv, REPEC…)
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
262
2275
S. Chatrchyan;V. Khachatryan;A. M. Sirunyan;A. Tumasyan;W. Adam;E. Aguilo;T. Bergauer;M. Dragicevic;J. Eroe;C. Fabjan;M. Friedl;R. Fruehwi...espandi
info:eu-repo/semantics/article
open
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
File Dimensione Formato  
jinst13_11_p11002.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 8.65 MB
Formato Adobe PDF
8.65 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/145105
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 29
social impact