Dental implants for prosthetic rehabilitation with fixed crown or mobile partial/total dentures is a very common oral treatment among the population in Italy as elsewhere. There is a great number of implant systems of different designs. However, a catalogue of radiographic images and a description of the dental implants available in Italy would be useful in order to identify the manufacturer and the type of implant encountered in forensic casework. When an unidentified body is found with one or more implants in the jaws, and no dental record is available, clues gleaned from the type of implants used could give direction to the investigation. In this study Italian implant manufactures were contacted and asked to provide specimen implants. Digital radiographs were taken of all the implants donated at 0, 30, and 60 horizontal rotation, combined with -20, -10, 0, +10, and +20 vertical inclination relative to the radiographic beam and the X-ray sensor. A total of 15 images per implant were taken and examined to identify consistent, unique features that would aid in implant recognition. Only those observations made from radiographs between -10 and +10 vertical inclination would ever be used for definite identification of any implant. The information from this study should be considered a survey of the commercial distribution of dental implants in Italy through their digital radiographic images. It is also a starting point for a wider geographical evaluation of different manufacturers in other countries and continents. The radiographic images provided should help both the forensic odontologist and the prosthodontist to identify pre-existing implants which they may discover from their radiographic images.
Radiographic dental implants recognition for geographic evaluation in human identification.
Nuzzolese E;DI VELLA, Giancarlo
2008-01-01
Abstract
Dental implants for prosthetic rehabilitation with fixed crown or mobile partial/total dentures is a very common oral treatment among the population in Italy as elsewhere. There is a great number of implant systems of different designs. However, a catalogue of radiographic images and a description of the dental implants available in Italy would be useful in order to identify the manufacturer and the type of implant encountered in forensic casework. When an unidentified body is found with one or more implants in the jaws, and no dental record is available, clues gleaned from the type of implants used could give direction to the investigation. In this study Italian implant manufactures were contacted and asked to provide specimen implants. Digital radiographs were taken of all the implants donated at 0, 30, and 60 horizontal rotation, combined with -20, -10, 0, +10, and +20 vertical inclination relative to the radiographic beam and the X-ray sensor. A total of 15 images per implant were taken and examined to identify consistent, unique features that would aid in implant recognition. Only those observations made from radiographs between -10 and +10 vertical inclination would ever be used for definite identification of any implant. The information from this study should be considered a survey of the commercial distribution of dental implants in Italy through their digital radiographic images. It is also a starting point for a wider geographical evaluation of different manufacturers in other countries and continents. The radiographic images provided should help both the forensic odontologist and the prosthodontist to identify pre-existing implants which they may discover from their radiographic images.File | Dimensione | Formato | |
---|---|---|---|
J Forensic Odontostomatol 2008, 27, 1, 8-11.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
97.77 kB
Formato
Adobe PDF
|
97.77 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.