Accidental electrocution during working activities account for a considerable amount of morbidity and mortality. Workers often misjudge the danger of electric wires or high-tension power cables, thereby exposing themselves to electrocution hazard. This article describes a nonfatal case of injuries by arcing from high-tension power-line cables involving a young farmer who was thrashing an olive tree by means of aluminum ladder. The circumstances surrounding the manner of electrocution and the features of electric injuries are presented and discussed.

Electrocution by Arcing A Nonfatal Case Study

DI VELLA, Giancarlo
2011-01-01

Abstract

Accidental electrocution during working activities account for a considerable amount of morbidity and mortality. Workers often misjudge the danger of electric wires or high-tension power cables, thereby exposing themselves to electrocution hazard. This article describes a nonfatal case of injuries by arcing from high-tension power-line cables involving a young farmer who was thrashing an olive tree by means of aluminum ladder. The circumstances surrounding the manner of electrocution and the features of electric injuries are presented and discussed.
2011
32
4
324
326
electrical injuries; arcing; battitura; aluminum ladder
Solarino B; Di Vella G
File in questo prodotto:
File Dimensione Formato  
AJFMP 2011 solarino di vella.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 765.78 kB
Formato Adobe PDF
765.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/145404
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact