The luminol test is routinely used in forensic serology to locate blood traces and identify blood stains not visible to the naked eye; its sensitivity is reported as ranging from 1:100.000 to 1:5.000.000. To evaluate the possibility of correlating the postmortem interval with blood remnants in bone tissue, the luminol test was performed on 80 femurs with a known time of death, grouped in five classes. Powdered bone (30 mg) was recovered from compact tissue of the mid-shaft of each femur and was treated with 0.1 mt of Luminol solution (Sirchie Finger Print Laboratories, Inc.). The reactions were observed in a dark room and filmed by a TV camera equipped with a recording tape. An intense chemiluminescence was observed after a few seconds in all 20 femurs with a PMI ranging from 1 month to 3 years. On the 20 femurs with a PMI ranging from 10-15 years, a clear chemiluminescence was visible with the naked eye in 80% of the sample. Among the 20 femurs with a PMI ranging from 25 to 35 years, a weaker chemiluminescence appeared in 7 femurs (33% of the sample). In the 10 femurs with a PMI ranging from 50 to 60 years, a faint reaction was observed only in a single femur. In none of the ten femurs with a PMI over 80 years was chemiluminescence observed. The image of each reaction was computerized and analyzed for gray scale. The results of image analysis show a possible quantitative relationship between the PMI and luminol chemiluminescence in powdered bone.

Determination of postmortem interval from old skeletal remains by image analysis of luminol test results

DI VELLA, Giancarlo;
1999-01-01

Abstract

The luminol test is routinely used in forensic serology to locate blood traces and identify blood stains not visible to the naked eye; its sensitivity is reported as ranging from 1:100.000 to 1:5.000.000. To evaluate the possibility of correlating the postmortem interval with blood remnants in bone tissue, the luminol test was performed on 80 femurs with a known time of death, grouped in five classes. Powdered bone (30 mg) was recovered from compact tissue of the mid-shaft of each femur and was treated with 0.1 mt of Luminol solution (Sirchie Finger Print Laboratories, Inc.). The reactions were observed in a dark room and filmed by a TV camera equipped with a recording tape. An intense chemiluminescence was observed after a few seconds in all 20 femurs with a PMI ranging from 1 month to 3 years. On the 20 femurs with a PMI ranging from 10-15 years, a clear chemiluminescence was visible with the naked eye in 80% of the sample. Among the 20 femurs with a PMI ranging from 25 to 35 years, a weaker chemiluminescence appeared in 7 femurs (33% of the sample). In the 10 femurs with a PMI ranging from 50 to 60 years, a faint reaction was observed only in a single femur. In none of the ten femurs with a PMI over 80 years was chemiluminescence observed. The image of each reaction was computerized and analyzed for gray scale. The results of image analysis show a possible quantitative relationship between the PMI and luminol chemiluminescence in powdered bone.
1999
44
3
535
538
forensic science; time since death; postmortem interval; skeletal remains; luminol test; image analysis
Introna F; Di Vella G; Campobasso CP
File in questo prodotto:
File Dimensione Formato  
JFS 1999, 44, 3, 535-38.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/145498
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 47
social impact