PURPOSE: The surgical removal of mandibular third molars is frequently accompanied by significant postsurgical sequelae, and different protocols have been described to decrease such adverse events. The aim of this study was to investigate the performance of piezosurgery compared with traditional rotating instruments during mandibular third molar removal. PATIENTS AND METHODS: A single-center, randomized, split-mouth study was performed using a consecutive series of unrelated healthy patients attending the Oral Surgery Unit of the University of Turin for surgical removal of bilateral mandibular third molar teeth. Each patient was treated, at the same appointment, using bur removal on 1 side of the mandible and a piezoelectric device on the contralateral side. The primary outcomes reported were postoperative pain, objective orofacial swelling, and surgical duration; secondary outcomes were gender, age, and possible adverse events. Analysis of variance or paired t test was used as appropriate to test any significant differences at baseline according to each treatment subgroup, and categorical variables were analyzed by χ(2) test. RESULTS: The study sample consisted of 100 otherwise healthy patients. The mean pain evaluation reported by patients who underwent surgery with piezosurgery was significantly lower than that reported after bur (conventional) removal, reaching statistical difference after 4 days (P = .043). The clinical value of orofacial swelling at day 7, normalized to baseline, was lower in the piezosurgery group (P < .005). The average surgical duration was significantly shorter in the bur group than in the piezosurgery group (P < .05). Three patients having bur removal developed short-term complications (2 dry sockets and 1 temporary paraesthesia), which totally resolved by 4 weeks. CONCLUSIONS: To date, this prospective investigation is the largest reported split-mouth study on piezosurgery for lower third molar tooth removal. This study also compared surgeons with different degrees of experience. It is evident that using a piezoelectric device can enhance the patient experience and decrease postoperative pain and swelling.

A split-mouth randomized clinical trial to evaluate the performance of piezosurgery compared with traditional technique in lower wisdom tooth removal.

ARDUINO, PAOLO GIACOMO;SCHIERANO, Gianmario;CAROSSA, Stefano
2014-01-01

Abstract

PURPOSE: The surgical removal of mandibular third molars is frequently accompanied by significant postsurgical sequelae, and different protocols have been described to decrease such adverse events. The aim of this study was to investigate the performance of piezosurgery compared with traditional rotating instruments during mandibular third molar removal. PATIENTS AND METHODS: A single-center, randomized, split-mouth study was performed using a consecutive series of unrelated healthy patients attending the Oral Surgery Unit of the University of Turin for surgical removal of bilateral mandibular third molar teeth. Each patient was treated, at the same appointment, using bur removal on 1 side of the mandible and a piezoelectric device on the contralateral side. The primary outcomes reported were postoperative pain, objective orofacial swelling, and surgical duration; secondary outcomes were gender, age, and possible adverse events. Analysis of variance or paired t test was used as appropriate to test any significant differences at baseline according to each treatment subgroup, and categorical variables were analyzed by χ(2) test. RESULTS: The study sample consisted of 100 otherwise healthy patients. The mean pain evaluation reported by patients who underwent surgery with piezosurgery was significantly lower than that reported after bur (conventional) removal, reaching statistical difference after 4 days (P = .043). The clinical value of orofacial swelling at day 7, normalized to baseline, was lower in the piezosurgery group (P < .005). The average surgical duration was significantly shorter in the bur group than in the piezosurgery group (P < .05). Three patients having bur removal developed short-term complications (2 dry sockets and 1 temporary paraesthesia), which totally resolved by 4 weeks. CONCLUSIONS: To date, this prospective investigation is the largest reported split-mouth study on piezosurgery for lower third molar tooth removal. This study also compared surgeons with different degrees of experience. It is evident that using a piezoelectric device can enhance the patient experience and decrease postoperative pain and swelling.
2014
72
10
1890
1897
Mantovani E;Arduino PG;Schierano G;Ferrero L;Gallesio G;Mozzati M;Russo A;Scully C;Carossa S
File in questo prodotto:
File Dimensione Formato  
Main text_mantovani arduinox.pdf

Open Access dal 01/11/2015

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 107.56 kB
Formato Adobe PDF
107.56 kB Adobe PDF Visualizza/Apri
1-s2.0-S0278239114005011-main.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/148684
Citazioni
  • ???jsp.display-item.citation.pmc??? 28
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 49
social impact