Objective of the study: To identify risk factors for the adverse events and determine the diagnostic yield of a large series of image-guided thoracic biopsies performed in a single institution. Materials and methods: We reviewed a consecutive series of 811 patients (546 males; average age: 68 years.) who underwent 824 image-guided biopsies of pulmonary lesions performed between 2009 and 2013. Indications for biopsy were always evaluated by a multidisciplinary board. All complications were registered. The diagnostic accuracy was calculated on the basis of histology after surgery, response to medical therapy, or outcome at imaging follow-up. Safety and accuracy was correlated with patient-related and lesion-related factors. Results: 61 biopsies were performed under US-guidance, 750 under CT-guidance, and 13 under combined guidance. The average lesion size was 36.4 mm (6–150 mm). FNAB was exclusively performed in 247 patients, whereas 577 patients underwent also or only core biopsy (CB). 40 (4.8 %) major complications and 172 (20.8 %) minor complications occurred. US-guidance, absence of perilesional emphysema and minor depth of the target lesion from the skin resulted as favorable predictors against major complications. According to the gold standard criteria, we demonstrated 497 true positives, 72 true negatives, 18 false negatives, 0 false positives. Sensitivity, specificity and diagnostic accuracy were 96.5, 100 and 97 %. No predictors for accuracy were found, but the number of samples largely related to the pathologist on site. Conclusions: Image-guided lung biopsy is safe and highly accurate for diagnosing thoracic lesions. In the targeted therapy era, CB with larger needles can be safely applied when the need for larger amounts of tumor tissue is presumed. © 2015, Italian Society of Medical Radiology.

Safety and diagnostic performance of image-guided lung biopsy in the targeted therapy era

RIGHI, Luisella;ARDISSONE, Francesco;NOVELLO, Silvia;PAPOTTI, Mauro Giulio;VELTRI, Andrea
Last
2015-01-01

Abstract

Objective of the study: To identify risk factors for the adverse events and determine the diagnostic yield of a large series of image-guided thoracic biopsies performed in a single institution. Materials and methods: We reviewed a consecutive series of 811 patients (546 males; average age: 68 years.) who underwent 824 image-guided biopsies of pulmonary lesions performed between 2009 and 2013. Indications for biopsy were always evaluated by a multidisciplinary board. All complications were registered. The diagnostic accuracy was calculated on the basis of histology after surgery, response to medical therapy, or outcome at imaging follow-up. Safety and accuracy was correlated with patient-related and lesion-related factors. Results: 61 biopsies were performed under US-guidance, 750 under CT-guidance, and 13 under combined guidance. The average lesion size was 36.4 mm (6–150 mm). FNAB was exclusively performed in 247 patients, whereas 577 patients underwent also or only core biopsy (CB). 40 (4.8 %) major complications and 172 (20.8 %) minor complications occurred. US-guidance, absence of perilesional emphysema and minor depth of the target lesion from the skin resulted as favorable predictors against major complications. According to the gold standard criteria, we demonstrated 497 true positives, 72 true negatives, 18 false negatives, 0 false positives. Sensitivity, specificity and diagnostic accuracy were 96.5, 100 and 97 %. No predictors for accuracy were found, but the number of samples largely related to the pathologist on site. Conclusions: Image-guided lung biopsy is safe and highly accurate for diagnosing thoracic lesions. In the targeted therapy era, CB with larger needles can be safely applied when the need for larger amounts of tumor tissue is presumed. © 2015, Italian Society of Medical Radiology.
2015
120
11
1024
1030
Marco Busso;Diego Sardo;Irene Garetto;Luisella Righi;Giulia Libero;Tiziana Vavalà;Francesco Ardissone;Silvia Novello;Mauro Papotti;Andrea Veltri
File in questo prodotto:
File Dimensione Formato  
Safety and diagnostic performance of image-guided lung biopsy in the targeted therapy era.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 519.83 kB
Formato Adobe PDF
519.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1509381
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact