OBJECTIVES: The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATERIALS AND METHODS: The local ethical committee approved this study. Consecutive immunological patients who have positive results for fecal immunological test who were scheduled for colonoscopy were enrolled for a 10-month period. Computed tomographic colonography studies were read with CAD (CAD COLON-1.20; im3D, Turin, Italy) by using both SR CAD (applied after unassisted interpretation primary 2-dimensional) and DR FR-CAD (CAD-prompts evaluation followed by a fast 2-dimensional review) in randomized order with the radiologist for each reading paradigm masked to the other reader's results.Per-patient sensitivity and specificity of unassisted and CAD-assisted readings for detecting 6-mm adenomas or larger were calculated by using unblinding colonoscopy as reference standard. Reporting times were also calculated. Pairwise comparisons were performed. RESULTS: A total of 182 participants (median age, 65 years; range, 58-76) were included in the final analysis. Of these, 93 (51%) had at least 1 cancer or a 6-mm adenoma or larger. At the 6-mm threshold, sensitivity of unassisted reading (79.6%; 95% confidence interval [CI], 69.9-87.2) increased significantly with the use of both SR CAD (86.0%; 95% CI, 77.3%-92.3%) and DR FR-CAD (89.2%; 95% CI, 81.1%-94.7%), without differences between CAD readings (P = 0.500). No significant differences in specificity among the 3 paradigms were observed. Double reading with first-reader CAD required less reading time than that for SR CAD (378 vs 496; Δ118 seconds; P < 0.001) and was 59 seconds longer than the unassisted reading (P = 0.058). CONCLUSIONS: When compared with unassisted reading, a double-reading paradigm in which first-reader CAD is followed by a fast 2-dimensional review improves the adenoma detection rate to the same level achieved by a second-reader CAD while decreasing reporting times.

Computer-aided detection for computed tomographic colonography screening: A prospective comparison of a double-reading paradigm with first-reader computer-aided detection against second-reader computer-aided detection

REGGE, Daniele
2014-01-01

Abstract

OBJECTIVES: The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATERIALS AND METHODS: The local ethical committee approved this study. Consecutive immunological patients who have positive results for fecal immunological test who were scheduled for colonoscopy were enrolled for a 10-month period. Computed tomographic colonography studies were read with CAD (CAD COLON-1.20; im3D, Turin, Italy) by using both SR CAD (applied after unassisted interpretation primary 2-dimensional) and DR FR-CAD (CAD-prompts evaluation followed by a fast 2-dimensional review) in randomized order with the radiologist for each reading paradigm masked to the other reader's results.Per-patient sensitivity and specificity of unassisted and CAD-assisted readings for detecting 6-mm adenomas or larger were calculated by using unblinding colonoscopy as reference standard. Reporting times were also calculated. Pairwise comparisons were performed. RESULTS: A total of 182 participants (median age, 65 years; range, 58-76) were included in the final analysis. Of these, 93 (51%) had at least 1 cancer or a 6-mm adenoma or larger. At the 6-mm threshold, sensitivity of unassisted reading (79.6%; 95% confidence interval [CI], 69.9-87.2) increased significantly with the use of both SR CAD (86.0%; 95% CI, 77.3%-92.3%) and DR FR-CAD (89.2%; 95% CI, 81.1%-94.7%), without differences between CAD readings (P = 0.500). No significant differences in specificity among the 3 paradigms were observed. Double reading with first-reader CAD required less reading time than that for SR CAD (378 vs 496; Δ118 seconds; P < 0.001) and was 59 seconds longer than the unassisted reading (P = 0.058). CONCLUSIONS: When compared with unassisted reading, a double-reading paradigm in which first-reader CAD is followed by a fast 2-dimensional review improves the adenoma detection rate to the same level achieved by a second-reader CAD while decreasing reporting times.
2014
49
3
173
182
http://www.scopus.com/inward/record.url?eid=2-s2.0-84894075373&partnerID=40&md5=10f520ef295f1ba0180d88b6c8d62fab
Iussich G; Correale L; Senore C; Hassan C; Segnan N; Campanella D; Bert A; Galatola G; Laudi C; Regge D.
File in questo prodotto:
File Dimensione Formato  
Computer-aided detection for computed .... 2014 Regge.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1529255
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact