INTRODUCTION: The management of patients with residual right-to-left shunt (rRLS) after percutaneous patent foramen ovale (PFO) closure is debated. The aim of this study was to define the incidence of moderate-to-large rRLS and to report the feasibility, safety and long-term clinical outcome of transcatheter closure of rRLS. METHODS AND RESULTS: From June 2000 to March 2013, 322 subjects underwent percutaneous PFO closure. In 39 patients (12.1%) with moderate-to-large rRLS on transcranial Doppler (TCD) and/or transesophageal echocardiogram a second cardiac catheterization was performed with the aim of completing the closure. A second closure device was implanted in 21 patients (53.8%). In the remaining 18 (46.2%), a second device was not delivered for the following reasons: in 13 (72.2%) no residual passage could be crossed, in 5 (27.8%) the residual shunt was deemed to be negligible. No complications occurred. After the second procedure, complete closure was proved by TCD in 16/21 (76.2%) subjects. One patient received a third device. During follow-up (41 ± 19 months), no cerebrovascular ischemic accidents occurred. CONCLUSION: A second percutaneous PFO occlusion device can be safely implanted in patients with significant rRLS. However, a moderate-to-large rRLS on TCD and/or TEE may not necessarily represent a significant risk of further paradoxical embolization.

Percutaneous implantation of a second device in patients with residual right-to-left shunt after patent foramen ovale closure.

ROVERA, Chiara;BIASCO, LUIGI;ORZAN, Fulvio;GAITA, Fiorenzo
2014-01-01

Abstract

INTRODUCTION: The management of patients with residual right-to-left shunt (rRLS) after percutaneous patent foramen ovale (PFO) closure is debated. The aim of this study was to define the incidence of moderate-to-large rRLS and to report the feasibility, safety and long-term clinical outcome of transcatheter closure of rRLS. METHODS AND RESULTS: From June 2000 to March 2013, 322 subjects underwent percutaneous PFO closure. In 39 patients (12.1%) with moderate-to-large rRLS on transcranial Doppler (TCD) and/or transesophageal echocardiogram a second cardiac catheterization was performed with the aim of completing the closure. A second closure device was implanted in 21 patients (53.8%). In the remaining 18 (46.2%), a second device was not delivered for the following reasons: in 13 (72.2%) no residual passage could be crossed, in 5 (27.8%) the residual shunt was deemed to be negligible. No complications occurred. After the second procedure, complete closure was proved by TCD in 16/21 (76.2%) subjects. One patient received a third device. During follow-up (41 ± 19 months), no cerebrovascular ischemic accidents occurred. CONCLUSION: A second percutaneous PFO occlusion device can be safely implanted in patients with significant rRLS. However, a moderate-to-large rRLS on TCD and/or TEE may not necessarily represent a significant risk of further paradoxical embolization.
2014
27
6
548
554
http://onlinelibrary.wiley.com/doi/10.1111/joic.12162/pdf
Rovera C;Biasco L;Orzan F;Belli R;Omedè P;Gaita F
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/156604
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact