Assessment of respirophasic fluctuations in the diameter of the inferior vena cava (IVC) is detrimentally affected by its concomitant displacements. This study was aimed at presenting and validating a method to compensate for IVC movement artifacts while continuously measuring IVC diameter in an automated fashion (with minimal interaction with the user) from a longitudinal B-mode ultrasound clip. Performance was tested on both experimental ultrasound clips collected from four healthy patients and simulations, implementing rigid IVC displacements and pulsation. Compared with traditional M-mode measurements, the new approach systematically reduced errors in caval index assessment (range over maximum diameter value) to an extent depending on individual vessel geometry, IVC movement and choice of the M-line (the line along which the diameter is computed). In experimental recordings, this approach identified both the cardiac and respiratory components of IVC movement and pulsatility and evidenced the spatial dependence of IVC pulsatility. IVC tracking appears to be a promising approach to reduce movement artifacts and to improve the reliability of IVC diameter monitoring

Semi-automated Tracking and Continuous Monitoring of Inferior Vena Cava Diameter in Simulated and Experimental Ultrasound Imaging.

ALBANI, Stefano;PORTA, Massimo;ROATTA, Silvestro
2015-01-01

Abstract

Assessment of respirophasic fluctuations in the diameter of the inferior vena cava (IVC) is detrimentally affected by its concomitant displacements. This study was aimed at presenting and validating a method to compensate for IVC movement artifacts while continuously measuring IVC diameter in an automated fashion (with minimal interaction with the user) from a longitudinal B-mode ultrasound clip. Performance was tested on both experimental ultrasound clips collected from four healthy patients and simulations, implementing rigid IVC displacements and pulsation. Compared with traditional M-mode measurements, the new approach systematically reduced errors in caval index assessment (range over maximum diameter value) to an extent depending on individual vessel geometry, IVC movement and choice of the M-line (the line along which the diameter is computed). In experimental recordings, this approach identified both the cardiac and respiratory components of IVC movement and pulsatility and evidenced the spatial dependence of IVC pulsatility. IVC tracking appears to be a promising approach to reduce movement artifacts and to improve the reliability of IVC diameter monitoring
2015
41
3
845
857
Mesin L;Pasquero P;Albani S;Porta M;Roatta S
File in questo prodotto:
File Dimensione Formato  
2015 Mesin et al Ultras Med Biol Caval vein tracking.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Mesin_et_al_UltrasMedBiol_2015_OA.pdf

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 883.55 kB
Formato Adobe PDF
883.55 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/158472
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 20
social impact