A microstructured graphitic 4 × 4 multi-electrode array was embedded in a single-crystal diamond substrate (4 × 4 μG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time-effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20 × 3.5 μm2) separated by 200 μm gaps. Taking advantage of the array geometry we addressed the following specific issues: (i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, (ii) resolve the waveform of different subsets of exocytotic events, and (iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 and 0.3 Hz, respectively, for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated with “full fusion” events, “kiss-and-run” and “kiss-and-stay” exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.

Microelectrode Arrays of Diamond-Insulated Graphitic Channels for Real-Time Detection of Exocytotic Events from Cultured Chromaffin Cells and Slices of Adrenal Glands

PICOLLO, FEDERICO;BATTIATO, ALFIO;BERNARDI, ETTORE;MARCANTONI, Andrea;CARBONE, Emilio;OLIVERO, Paolo;CARABELLI, Valentina
Last
2016-01-01

Abstract

A microstructured graphitic 4 × 4 multi-electrode array was embedded in a single-crystal diamond substrate (4 × 4 μG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time-effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20 × 3.5 μm2) separated by 200 μm gaps. Taking advantage of the array geometry we addressed the following specific issues: (i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, (ii) resolve the waveform of different subsets of exocytotic events, and (iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 and 0.3 Hz, respectively, for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated with “full fusion” events, “kiss-and-run” and “kiss-and-stay” exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.
2016
Inglese
Esperti anonimi
88
15
7493
7499
7
http://pubs.acs.org/doi/abs/10.1021/acs.analchem.5b04449
Diamond, Multielectrode array, Cell sensing
GERMANIA
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
262
8
Picollo, Federico; Battiato, Alfio; Bernardi, Ettore; Marcantoni, Andrea; Pasquarelli, Alberto; Carbone, Emilio; Olivero, Paolo; Carabelli, Valentina...espandi
info:eu-repo/semantics/article
partially_open
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
File Dimensione Formato  
AC_88_7493.pdf

Accesso riservato

Descrizione: AC_88_7493
Tipo di file: PDF EDITORIALE
Dimensione 2 MB
Formato Adobe PDF
2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
AC_88_7493_AperTo.pdf

Open Access dal 05/07/2017

Descrizione: AC_88_7493_AperTo
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.77 MB
Formato Adobe PDF
1.77 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1589408
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 26
social impact