This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA. (J Rheumatol 2011;38:2063-7; doi:10.3899/jrheum.110425)

The OMERACT Ultrasound Task Force - Status and Perspectives

IAGNOCCO, Annamaria;
2011-01-01

Abstract

This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA. (J Rheumatol 2011;38:2063-7; doi:10.3899/jrheum.110425)
2011
38
9
2063
2067
http://www.jrheum.org/content/38/9/2063.long
enthesitis; omeract; power doppler; standardization; synovitis; ultrasound
E. Naredo; R.J. Wakefield; Annamaria Iagnocco; L. Terslev; E. Filippucci; F. Gandjbakhch; P. Aegerter; S. Aydin; M. Backhaus; P.V. Balint; G.A.W. Bruyn; P. Collado; S. Finzel; J.E. Freeston; M. Gutierrez; F. Joshua; S. Jousse-Joulin; D. Kane; H.I. Keen; I. Moller; P. Mandl; S. Ohrndorf; C. Pineda; W.A. Schmidt; M. Szkudlarek; P.G. Conaghan; M.A. D'Agostino
File in questo prodotto:
File Dimensione Formato  
J Rheumatol-2011-NAREDO-2063-7.pdf

Accesso aperto

Dimensione 155.21 kB
Formato Adobe PDF
155.21 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1613100
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 100
  • ???jsp.display-item.citation.isi??? 94
social impact