Objective. To compare the carotid intima-media thickness (IMT) assessed with automated radiofrequency-based US in RA patients treated with synthetic vs synthetic and biologic DMARDs and controls. Methods. Ninety-four RA patients and 94 sex-and age-matched controls were prospectively recruited at seven centres. Cardiovascular (CV) risk factors and co-morbidities, RA characteristics and therapy were recorded. Common carotid artery (CCA)-IMT was assessed in RA patients and controls with automated radiofrequency-based US by the same investigator at each centre. Results. Forty-five (47.9%) RA patients had been treated with synthetic DMARDs and 49 (52.1%) with synthetic and biologic DMARDs. There were no significant differences between the RA patients and controls in demographics, CV co-morbidities and CV disease. There were significantly more smokers among RA patients treated with synthetic and biologic DMARDs (P = 0.036). Disease duration and duration of CS and synthetic DMARD therapy was significantly longer in RA patients treated with synthetic and biologic DMARDs (P<0.0005). The mean CCA-IMT was significantly greater in RA patients treated only with synthetic DMARDs than in controls [591.4 (98.6) vs 562.1 (85.8); P = 0.035] and in RA patients treated with synthetic and biologic DMARDs [591.4 (98.6) vs 558.8 (95.3); P = 0.040). There was no significant difference between the mean CCA-IMT in RA patients treated with synthetic and biologic DMARDs and controls (P = 0.997). Conclusion. Our results suggest that radiofrequency-based measurement of CCA-IMT can discriminate between RA patients treated with synthetic DMARDs vs RA patients treated with synthetic and biologic DMARDs.

Automated radiofrequency-based US measurement of common carotid intima-media thickness in RA patients treated with synthetic vs synthetic and biologic DMARDs

IAGNOCCO, Annamaria;
2013-01-01

Abstract

Objective. To compare the carotid intima-media thickness (IMT) assessed with automated radiofrequency-based US in RA patients treated with synthetic vs synthetic and biologic DMARDs and controls. Methods. Ninety-four RA patients and 94 sex-and age-matched controls were prospectively recruited at seven centres. Cardiovascular (CV) risk factors and co-morbidities, RA characteristics and therapy were recorded. Common carotid artery (CCA)-IMT was assessed in RA patients and controls with automated radiofrequency-based US by the same investigator at each centre. Results. Forty-five (47.9%) RA patients had been treated with synthetic DMARDs and 49 (52.1%) with synthetic and biologic DMARDs. There were no significant differences between the RA patients and controls in demographics, CV co-morbidities and CV disease. There were significantly more smokers among RA patients treated with synthetic and biologic DMARDs (P = 0.036). Disease duration and duration of CS and synthetic DMARD therapy was significantly longer in RA patients treated with synthetic and biologic DMARDs (P<0.0005). The mean CCA-IMT was significantly greater in RA patients treated only with synthetic DMARDs than in controls [591.4 (98.6) vs 562.1 (85.8); P = 0.035] and in RA patients treated with synthetic and biologic DMARDs [591.4 (98.6) vs 558.8 (95.3); P = 0.040). There was no significant difference between the mean CCA-IMT in RA patients treated with synthetic and biologic DMARDs and controls (P = 0.997). Conclusion. Our results suggest that radiofrequency-based measurement of CCA-IMT can discriminate between RA patients treated with synthetic DMARDs vs RA patients treated with synthetic and biologic DMARDs.
2013
52
2
376
381
carotid intima-media thickness; radiofrequency; rheumatoid arthritis; ultrasound
E. Naredo; I. Moller; A. Corrales; D.A. Bong; T. Cobo-Ibanez; H. Corominas; M.L. Garcia-Vivar; P. Macarron; T. Navio; P. Richi; Annamaria Iagnocco; J....espandi
File in questo prodotto:
File Dimensione Formato  
65.pdf

Accesso aperto

Dimensione 85 kB
Formato Adobe PDF
85 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1613151
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact