Purpose. To investigate retinal function using microperimetry in patients affected by idiopathic epiretinal membrane (iERM) and cataract who underwent combined surgery: 4-year follow-up. Design. Prospective, interventional case series. Methods. 30 eyes of 30 consecutive patients with iERM and age-related cataract underwent 25-gauge vitrectomy and cataract surgery. At baseline, 90 and 180 days, and 1 and 4 years, we examined retinal mean sensitivity (MS), retinal mean defect (MD), fixation stability, and frequency of microscotomas using MP1 microperimetry. Best-corrected visual acuity (BCVA) and central retinal thickness (CRT) using a spectral domain optical coherence tomography (SD-OCT) were also performed. Results. All patients completed 1-year follow-up, while 23 patients reached last follow-up. Baseline MS and MD (10.48 ± 4.17 and -9.18 ± 4.40 dB) significantly changed at one year (12.33 ± 3.66 and -7.49 ± 3.31 dB, p < 0.01), at four years (14.18 ± 3.46 and -4.66 ± 2.85, p < 0.01), and between one and four years (p < 0.01) after surgery. Compared to baseline, CRT and BCVA significantly changed at one year and remained stable at four years. No variations were observed in fixation stability and frequency of microscotomas compared to baseline. Conclusions. Long-term follow-up using microperimetry seems useful to evaluate patients after iERM surgery: retinal sensitivity changes even when BCVA and CRT remain stable.
Microperimetric assessment after epiretinal membrane surgery: 4-year follow-up
FEA, Antonio Maria
Last
2016-01-01
Abstract
Purpose. To investigate retinal function using microperimetry in patients affected by idiopathic epiretinal membrane (iERM) and cataract who underwent combined surgery: 4-year follow-up. Design. Prospective, interventional case series. Methods. 30 eyes of 30 consecutive patients with iERM and age-related cataract underwent 25-gauge vitrectomy and cataract surgery. At baseline, 90 and 180 days, and 1 and 4 years, we examined retinal mean sensitivity (MS), retinal mean defect (MD), fixation stability, and frequency of microscotomas using MP1 microperimetry. Best-corrected visual acuity (BCVA) and central retinal thickness (CRT) using a spectral domain optical coherence tomography (SD-OCT) were also performed. Results. All patients completed 1-year follow-up, while 23 patients reached last follow-up. Baseline MS and MD (10.48 ± 4.17 and -9.18 ± 4.40 dB) significantly changed at one year (12.33 ± 3.66 and -7.49 ± 3.31 dB, p < 0.01), at four years (14.18 ± 3.46 and -4.66 ± 2.85, p < 0.01), and between one and four years (p < 0.01) after surgery. Compared to baseline, CRT and BCVA significantly changed at one year and remained stable at four years. No variations were observed in fixation stability and frequency of microscotomas compared to baseline. Conclusions. Long-term follow-up using microperimetry seems useful to evaluate patients after iERM surgery: retinal sensitivity changes even when BCVA and CRT remain stable.File | Dimensione | Formato | |
---|---|---|---|
Jour_Ophthal_2016_Fea.pdf
Accesso aperto
Tipo di file:
PDF EDITORIALE
Dimensione
571.58 kB
Formato
Adobe PDF
|
571.58 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.