BACKGROUND: Synthetic mesh (SM) has been used in the laparoscopic repair of hiatus hernia but remains controversial due to reports of complications, most notably esophageal erosion. Biological mesh (BM) has been proposed as an alternative to mitigate this risk. The aim of this study is to establish the incidence of complications, recurrence and revision surgery in patients following suture (SR), SM or BM repair and undertake a survey of surgeons to establish a perspective of current practice. METHODS: An electronic search of EMBASE, MEDLINE and Cochrane database was performed. Pooled odds ratios (PORs) were calculated for discrete variables. To survey current practice an online questionnaire was sent to emails registered to the European Association for Endoscopic Surgery. RESULTS: Nine studies were included, comprising 676 patients (310 with SR, 214 with SM and 152 with BM). There was no significant difference in the incidence of complications with mesh compared to SR (P = 0.993). Mesh significantly reduced overall recurrence rates compared to SR [14.5 vs. 24.5 %; POR = 0.36 (95 % CI 0.17-0.77); P = 0.009]. Overall recurrence rates were reduced in the SM compared to BM groups (12.6 vs. 17.1 %), and similarly compared to the SR group, the POR for recurrence was lower in the SM group than the BM group [0.30 (95 % CI 0.12-0.73); P = 0.008 vs. 0.69 (95 % CI 0.26-1.83); P = 0.457]. Regarding surgical technique 503 survey responses were included. Mesh reinforcement of the crura was undertaken by 67 % of surgeons in all or selected cases with 67 % of these preferring synthetic mesh to absorbable mesh. One-fifth of the respondents had encountered mesh erosion in their career. CONCLUSIONS: Both SM and BM reduce rates of recurrence compared to SR, with SM proving most effective. Surgical practice is varied, and there remains insufficient evidence regarding the optimum technique for the repair of hiatal hernia.

Laparoscopic repair of hiatus hernia: Does mesh type influence outcome? A meta-analysis and European survey study

MORINO, Mario;
2016-01-01

Abstract

BACKGROUND: Synthetic mesh (SM) has been used in the laparoscopic repair of hiatus hernia but remains controversial due to reports of complications, most notably esophageal erosion. Biological mesh (BM) has been proposed as an alternative to mitigate this risk. The aim of this study is to establish the incidence of complications, recurrence and revision surgery in patients following suture (SR), SM or BM repair and undertake a survey of surgeons to establish a perspective of current practice. METHODS: An electronic search of EMBASE, MEDLINE and Cochrane database was performed. Pooled odds ratios (PORs) were calculated for discrete variables. To survey current practice an online questionnaire was sent to emails registered to the European Association for Endoscopic Surgery. RESULTS: Nine studies were included, comprising 676 patients (310 with SR, 214 with SM and 152 with BM). There was no significant difference in the incidence of complications with mesh compared to SR (P = 0.993). Mesh significantly reduced overall recurrence rates compared to SR [14.5 vs. 24.5 %; POR = 0.36 (95 % CI 0.17-0.77); P = 0.009]. Overall recurrence rates were reduced in the SM compared to BM groups (12.6 vs. 17.1 %), and similarly compared to the SR group, the POR for recurrence was lower in the SM group than the BM group [0.30 (95 % CI 0.12-0.73); P = 0.008 vs. 0.69 (95 % CI 0.26-1.83); P = 0.457]. Regarding surgical technique 503 survey responses were included. Mesh reinforcement of the crura was undertaken by 67 % of surgeons in all or selected cases with 67 % of these preferring synthetic mesh to absorbable mesh. One-fifth of the respondents had encountered mesh erosion in their career. CONCLUSIONS: Both SM and BM reduce rates of recurrence compared to SR, with SM proving most effective. Surgical practice is varied, and there remains insufficient evidence regarding the optimum technique for the repair of hiatal hernia.
2016
30
12
5209
5221
http://link.springer.com/article/10.1007%2Fs00464-016-4900-3
Hiatal hernia; Laparoscopy; Mesh; Surgery
Huddy, Jeremy R.; Markar, Sheraz R.; Ni, Melody Z.; Morino, Mario; Targarona, Edoardo M.; Zaninotto, Giovanni; Hanna, George B
File in questo prodotto:
File Dimensione Formato  
laparoscopic repairart%3A10.1007%2Fs00464-016-4900-3.pdf

Accesso riservato

Descrizione: pfd editoriale ad accesso chiuso
Tipo di file: PDF EDITORIALE
Dimensione 1.8 MB
Formato Adobe PDF
1.8 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
OALaparoscopic repair of hiatus hernia_4aperto.pdf

Open Access dal 01/01/2018

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 688.58 kB
Formato Adobe PDF
688.58 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1620930
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 62
social impact