PURPOSE: Catheter ablation of the slow pathway is the most effective treatment for atrioventricular nodal reentrant tachycardia (AVNRT). Cryoenergy, compared to radiofrequency, relates to lower heart block risk but higher incidence of AVNRT recurrences. The aims of this study are to confirm the safety and efficacy of AVNRT cryoablation and to identify predictors of long-term recurrences. METHODS: Among 241 patients undergoing AVNRT cryoablation, 239 (99.2%) experienced acute effective cryoablation of the slow pathway, and no procedure-related complications were reported. RESULTS: After a follow-up of 44.9 ± 31.7 months, 28 (11.7%) patients presented AVNRT recurrences. A shorter preablation (p = 0.05) and postablation anterograde Wenckebach cycle length (p < 0.01), a shorter postablation atrioventricular node refractory period (p = 0.04), and persistence of the crossover sign (p = 0.03) were associated with higher incidence of long-term recurrences. Considering cooling dynamics, a longer time to reach temperature ≤-70 °C (p = 0.03) and a higher minimal temperature during ablation (p = 0.04) were related to recurrences. Patients without residual markers of dual AV node physiology (AH jump, single atrial echo beat, crossover) reported a lower recurrence rate (p = 0.05) compared to those without. At multivariate analysis, a longer time to -70 °C was the strongest independent predictor of long-term recurrence (OR 1.75, 95% CI 1.01-3.03, p = 0.04). CONCLUSIONS: AVNRT cryoablation is safe and effective. Long-term recurrence rate was 11.7%. An ablation approach directed to the complete elimination of dual AV node physiology, along with assessment of the tissue's cooling dynamics, holds the potential to improve long-term AVNRT cryoablation efficacy.

Cooling dynamics: a new predictor of long-term efficacy of atrioventricular nodal reentrant tachycardia cryoablation

MATTA, Mario;ANSELMINO, Matteo;CASTAGNO, Davide;GAITA, Fiorenzo
2017-01-01

Abstract

PURPOSE: Catheter ablation of the slow pathway is the most effective treatment for atrioventricular nodal reentrant tachycardia (AVNRT). Cryoenergy, compared to radiofrequency, relates to lower heart block risk but higher incidence of AVNRT recurrences. The aims of this study are to confirm the safety and efficacy of AVNRT cryoablation and to identify predictors of long-term recurrences. METHODS: Among 241 patients undergoing AVNRT cryoablation, 239 (99.2%) experienced acute effective cryoablation of the slow pathway, and no procedure-related complications were reported. RESULTS: After a follow-up of 44.9 ± 31.7 months, 28 (11.7%) patients presented AVNRT recurrences. A shorter preablation (p = 0.05) and postablation anterograde Wenckebach cycle length (p < 0.01), a shorter postablation atrioventricular node refractory period (p = 0.04), and persistence of the crossover sign (p = 0.03) were associated with higher incidence of long-term recurrences. Considering cooling dynamics, a longer time to reach temperature ≤-70 °C (p = 0.03) and a higher minimal temperature during ablation (p = 0.04) were related to recurrences. Patients without residual markers of dual AV node physiology (AH jump, single atrial echo beat, crossover) reported a lower recurrence rate (p = 0.05) compared to those without. At multivariate analysis, a longer time to -70 °C was the strongest independent predictor of long-term recurrence (OR 1.75, 95% CI 1.01-3.03, p = 0.04). CONCLUSIONS: AVNRT cryoablation is safe and effective. Long-term recurrence rate was 11.7%. An ablation approach directed to the complete elimination of dual AV node physiology, along with assessment of the tissue's cooling dynamics, holds the potential to improve long-term AVNRT cryoablation efficacy.
2017
48
3
333
341
www.wkap.nl/journalhome.htm/1383-875X
AVNRT; Cooling dynamics; Cryoablation; Slow pathway; Supraventricular tachycardia; Cardiology and Cardiovascular Medicine; Physiology (medical)
Matta, Mario; Anselmino, Matteo; Scaglione, Marco; Vitolo, Marco; Ferraris, Federico; Di Donna, Paolo; Caponi, Domenico; Castagno, Davide; Gaita, Fior...espandi
File in questo prodotto:
File Dimensione Formato  
Accepted con copertina.pdf

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 803.71 kB
Formato Adobe PDF
803.71 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1624216
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact