Abstract BACKGROUND: To compare the reduction of intraocular pressure (IOP) and glaucoma medications following selective laser trabeculoplasty (SLT) versus stand-alone placement of the Hydrus microstent, a microinvasive glaucoma surgery device. DESIGN: Prospective interventional case-series. University practice. PARTICIPANTS: Fifty six eyes (56 patients) with uncontrolled primary open-angle glaucoma. METHODS: Patients received either SLT (n = 25) or Hydrus implantation (n = 31) in two centres. Patients were evaluated at baseline and 1, 7 days, 1, 3, 6 and 12 months after surgery. MAIN OUTCOME MEASURES: Intraocular pressure and number of glaucoma medications variations inter-groups and intra-groups. RESULTS: There were no significant differences at baseline between groups, but the mean deviation was worse in the Hydrus group (-8.43 ± 6.84 dB, confidence limits (CL)-2.8/-3.3 vs.-3.04 ± 0.65 dB, CL-6/-10.8; P < 0.001). After 12 months, there was a significant decrease in IOP and medications in the Hydrus group compared with baseline values. In the SLT group, only the decrease in IOP was significant. There was 3-fold greater reduction in medication use in the Hydrus group compared with SLT (-1.4 ± 0.97 vs.-0.5 ± 1.05, P = 0.001). 47% of patients were medication free at 12 months in the Hydrus group (4% in the SLT group). No complications were recorded in the SLT group. In the Hydrus group, three patients experienced a temporary reduction of visual acuity post-operatively, and two patients had post-operative IOP spikes that resolved within one week. CONCLUSIONS: Both SLT and Hydrus implantation reduced IOP without serious adverse events. Hydrus implantation led to a significant and further reduction in medication dependence at 12 months.
Hydrus microstent compared to selective laser trabeculoplasty in primary open angle glaucoma: one year results
FEA, Antonio Maria
First
;LAVIA, Carlo Alessandro;CONSOLANDI, Giulia;PIGNATA, Giulia;ROLLE, Teresa;
2017-01-01
Abstract
Abstract BACKGROUND: To compare the reduction of intraocular pressure (IOP) and glaucoma medications following selective laser trabeculoplasty (SLT) versus stand-alone placement of the Hydrus microstent, a microinvasive glaucoma surgery device. DESIGN: Prospective interventional case-series. University practice. PARTICIPANTS: Fifty six eyes (56 patients) with uncontrolled primary open-angle glaucoma. METHODS: Patients received either SLT (n = 25) or Hydrus implantation (n = 31) in two centres. Patients were evaluated at baseline and 1, 7 days, 1, 3, 6 and 12 months after surgery. MAIN OUTCOME MEASURES: Intraocular pressure and number of glaucoma medications variations inter-groups and intra-groups. RESULTS: There were no significant differences at baseline between groups, but the mean deviation was worse in the Hydrus group (-8.43 ± 6.84 dB, confidence limits (CL)-2.8/-3.3 vs.-3.04 ± 0.65 dB, CL-6/-10.8; P < 0.001). After 12 months, there was a significant decrease in IOP and medications in the Hydrus group compared with baseline values. In the SLT group, only the decrease in IOP was significant. There was 3-fold greater reduction in medication use in the Hydrus group compared with SLT (-1.4 ± 0.97 vs.-0.5 ± 1.05, P = 0.001). 47% of patients were medication free at 12 months in the Hydrus group (4% in the SLT group). No complications were recorded in the SLT group. In the Hydrus group, three patients experienced a temporary reduction of visual acuity post-operatively, and two patients had post-operative IOP spikes that resolved within one week. CONCLUSIONS: Both SLT and Hydrus implantation reduced IOP without serious adverse events. Hydrus implantation led to a significant and further reduction in medication dependence at 12 months.File | Dimensione | Formato | |
---|---|---|---|
Hydrus microstent compared to selective laser trabeculoplasty.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
537.15 kB
Formato
Adobe PDF
|
537.15 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Clinical and Experimental Ophthalmology 2017.pdf
Accesso aperto
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
503.52 kB
Formato
Adobe PDF
|
503.52 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.