A small-sized bioprosthesis can limit transcatheter valve-in-valve (V-in-V) implantations. The case is reported of a 91-year-old woman who had successfully undergone a V-in-V procedure with a 26 mm CoreValve in a previously implanted Mitroflow 19 mm valve. At the five-year follow up the prosthesis showed good echocardiographic function and the patient was alive and free from major symptoms. The patient died three months after the follow up examination at the age of 96 years. This case demonstrates the feasibility, with acceptable longterm functioning, of a V-in-V procedure involving a small bioprosthesis. To the authors' knowledge, the present report is the longest follow up of a patient who underwent V-in-V transcatheter aortic valve implantation in a 19 mm bioprosthesis (15.4 mm internal diameter). Video 1: Preoperative aortography showing moderate-to-severe aortic regurgitation. Video 2: Pre-implantation aortic balloon valvuloplasty. Video 3: Post-deployment aortography showing moderate-to-severe aortic regurgitation. Video 4: The final result. After post-dilation of the under-expanded 26 mm CoreValve, the aortic regurgitation is slightly reduced.

Transfemoral Valve-In-Valve in a Degenerated Small Aortic Bioprosthesis: Five-Year Follow Up

Salizzoni, Stefano;RINALDI, Mauro;FERRARO, GAETANA;
2017-01-01

Abstract

A small-sized bioprosthesis can limit transcatheter valve-in-valve (V-in-V) implantations. The case is reported of a 91-year-old woman who had successfully undergone a V-in-V procedure with a 26 mm CoreValve in a previously implanted Mitroflow 19 mm valve. At the five-year follow up the prosthesis showed good echocardiographic function and the patient was alive and free from major symptoms. The patient died three months after the follow up examination at the age of 96 years. This case demonstrates the feasibility, with acceptable longterm functioning, of a V-in-V procedure involving a small bioprosthesis. To the authors' knowledge, the present report is the longest follow up of a patient who underwent V-in-V transcatheter aortic valve implantation in a 19 mm bioprosthesis (15.4 mm internal diameter). Video 1: Preoperative aortography showing moderate-to-severe aortic regurgitation. Video 2: Pre-implantation aortic balloon valvuloplasty. Video 3: Post-deployment aortography showing moderate-to-severe aortic regurgitation. Video 4: The final result. After post-dilation of the under-expanded 26 mm CoreValve, the aortic regurgitation is slightly reduced.
2017
26
1
118
120
Salizzoni, Stefano; Conrotto, Federico; Rinaldi, Mauro; Paolo Ussia, Gian; Ferraro, Gaetana; Giorgi, Mauro; D'Amico, Maurizio
File in questo prodotto:
File Dimensione Formato  
Transfemoral.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 471.63 kB
Formato Adobe PDF
471.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1646739
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact