To evaluate motion artifacts, breath-hold failure, acute transient dyspnea, and clinical parameters during hepatic arterial phase of gadoxetate disodium-enhanced magnetic resonance (MR) imaging. METHODS: This was an institutional review board-approved observational prospective study (written informed consent acquired) performed in 250 consecutive patients, who underwent liver MR with a multiarterial phase technique. Oxygen saturation (SatO2) and heart rate (HR) were monitored, while patients reported subjective symptoms. Breath-holds were assessed using prospective acquisition correction technique (PACE) monitors. Three readers independently analyzed all images to establish the presence of motion artifacts. Nonparametric statistical testing and Fleiss' kappa were used. RESULTS: No statistical differences in SatO2 and HR values were observed during the entire length of MR examination. The PACE graphs showed an altered breath-hold in 16/250 patients (6.4%), however only 6 patients self-reported symptoms during the procedure, and among these 6 subjects, only 2 suffered from acute transient dyspnea (0.8%). Motion-related artifacts increased mostly in the third arterial phase of gadoxetate disodium acquisition (p < 0.0001): The artifacts incidence was 2.9% in the first phase; 4.0% in the second; and 19.5% in the third. This increase was mainly due to patients' inability to hold their breath for the entire duration of the examination. However, at least one gadoxetate disodium arterial phase without motion artifacts and adequate for acquisition timing, was acquired in all MR examinations. CONCLUSION: The incidence of breath-hold failure and acute transient dyspnea after gadoxetate disodium administration increased during the third arterial phase only. Our protocol allowed the acquisition of at least one arterial phase not compromised by motion artifacts and adequate for acquisition timing, in all patients.

Evaluation of incidence of acute transient dyspnea and related artifacts after administration of gadoxetate disodium: a prospective observational study

Faletti, R
;
Battisti, G;GATTI, Marco;Fonio, P
Last
2018-01-01

Abstract

To evaluate motion artifacts, breath-hold failure, acute transient dyspnea, and clinical parameters during hepatic arterial phase of gadoxetate disodium-enhanced magnetic resonance (MR) imaging. METHODS: This was an institutional review board-approved observational prospective study (written informed consent acquired) performed in 250 consecutive patients, who underwent liver MR with a multiarterial phase technique. Oxygen saturation (SatO2) and heart rate (HR) were monitored, while patients reported subjective symptoms. Breath-holds were assessed using prospective acquisition correction technique (PACE) monitors. Three readers independently analyzed all images to establish the presence of motion artifacts. Nonparametric statistical testing and Fleiss' kappa were used. RESULTS: No statistical differences in SatO2 and HR values were observed during the entire length of MR examination. The PACE graphs showed an altered breath-hold in 16/250 patients (6.4%), however only 6 patients self-reported symptoms during the procedure, and among these 6 subjects, only 2 suffered from acute transient dyspnea (0.8%). Motion-related artifacts increased mostly in the third arterial phase of gadoxetate disodium acquisition (p < 0.0001): The artifacts incidence was 2.9% in the first phase; 4.0% in the second; and 19.5% in the third. This increase was mainly due to patients' inability to hold their breath for the entire duration of the examination. However, at least one gadoxetate disodium arterial phase without motion artifacts and adequate for acquisition timing, was acquired in all MR examinations. CONCLUSION: The incidence of breath-hold failure and acute transient dyspnea after gadoxetate disodium administration increased during the third arterial phase only. Our protocol allowed the acquisition of at least one arterial phase not compromised by motion artifacts and adequate for acquisition timing, in all patients.
2018
123
12
910
917
http://link.springer.com/journal/11547
Arterial phase; Artifact; Gadoxetate disodium; Liver; Magnetic resonance imaging; Motion artifact; Radiology, Nuclear Medicine and Imaging
Grazioli, L; Faletti, R; Frittoli, B; Battisti, G; Ambrosini, R; Romanini, L; Gatti, M; Fonio, P
File in questo prodotto:
File Dimensione Formato  
Grazioli2018_Article_EvaluationOfIncidenceOfAcuteTr.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1678814
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact