Pseudomonas aeruginosa is an environmental bacterium, ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). We investigated the prevalence of P. aeruginosa in DUWLs from private dental settings. We also analyzed the relationship between P. aeruginosa contamination and the presence of Legionella spp. and total viable count (TVC) in order to suggest a simple and inexpensive protocol to test the quality of water from DUWLs. We detected and quantified P. aeruginosa both by culture and by a PMA (propidium monoazide)-qPCR method. Overall, we detected P. aeruginosa in 17 samples using the PMA-qPCR and in 11 samples using the culture. All culture-positive samples were positive with the PMA-qPCR too, with an agreement between the two methods of 93% and a Cohen's kappa coefficient of k = 0.747 (good concordance). Comparing results with results of our previous study, we noted that (a) P. aeruginosa was isolated only from DUWLs with high TVC and (b) five out of six Legionella-positive samples were negative for Pseudomonas spp. Our final suggestion is that the cleanliness of DUWLs should be assessed by TVC because it is a good indicator of the presence of pathogens such as Legionella spp. and P. aeruginosa.

Colonization by Pseudomonas aeruginosa of dental unit waterlines and its relationship with other bacteria: Suggestions for microbiological monitoring

Ditommaso S.;Giacomuzzi M.;Memoli G.;Zotti C. M.
Last
2019-01-01

Abstract

Pseudomonas aeruginosa is an environmental bacterium, ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). We investigated the prevalence of P. aeruginosa in DUWLs from private dental settings. We also analyzed the relationship between P. aeruginosa contamination and the presence of Legionella spp. and total viable count (TVC) in order to suggest a simple and inexpensive protocol to test the quality of water from DUWLs. We detected and quantified P. aeruginosa both by culture and by a PMA (propidium monoazide)-qPCR method. Overall, we detected P. aeruginosa in 17 samples using the PMA-qPCR and in 11 samples using the culture. All culture-positive samples were positive with the PMA-qPCR too, with an agreement between the two methods of 93% and a Cohen's kappa coefficient of k = 0.747 (good concordance). Comparing results with results of our previous study, we noted that (a) P. aeruginosa was isolated only from DUWLs with high TVC and (b) five out of six Legionella-positive samples were negative for Pseudomonas spp. Our final suggestion is that the cleanliness of DUWLs should be assessed by TVC because it is a good indicator of the presence of pathogens such as Legionella spp. and P. aeruginosa.
2019
17
4
532
539
https://watermark.silverchair.com/jwh0170532.pdf
Dental setting; Enumeration; Pseudomonas spp.; Quantitative real-time PCR; Total viable count; Bacteria; Equipment Contamination; Pseudomonas aeruginosa; Dental Equipment; Water Microbiology
Ditommaso S.; Giacomuzzi M.; Ricciardi E.; Memoli G.; Zotti C.M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1730747
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact