IntroductionAtrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO). We evaluated this methodology in a large sample size of patients and a multicentre experience.Methods and resultsTwo hundred and fifty paroxysmal atrial fibrillation patients referred for first atrial fibrillation ablation with a CARTO3 electroanatomic mapping system were enrolled. In 58 out of 250 patients, a PFO allowed crossing of the interatrial septum, and a completely fluoroless ablation was performed applying the new method (Group A). In the remaining patients, a standard transseptal puncture was performed (Group B). Pulmonary vein isolation was achieved in all patients with comparable procedural and clinical outcomes at short- and long-term follow-up.ConclusionThe presence of a PFO may allow a completely fluoroless well tolerated and effective atrial fibrillation ablation. Probing the fossa ovalis looking for the PFO during the procedure is desirable, as it is not time-consuming and can potentially be done in every patient undergoing atrial fibrillation ablation.

Zero-fluoroscopy atrial fibrillation ablation in the presence of a patent foramen ovale: a multicentre experience

Anselmino M.;Castagno D.;Gaita F.
2020-01-01

Abstract

IntroductionAtrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO). We evaluated this methodology in a large sample size of patients and a multicentre experience.Methods and resultsTwo hundred and fifty paroxysmal atrial fibrillation patients referred for first atrial fibrillation ablation with a CARTO3 electroanatomic mapping system were enrolled. In 58 out of 250 patients, a PFO allowed crossing of the interatrial septum, and a completely fluoroless ablation was performed applying the new method (Group A). In the remaining patients, a standard transseptal puncture was performed (Group B). Pulmonary vein isolation was achieved in all patients with comparable procedural and clinical outcomes at short- and long-term follow-up.ConclusionThe presence of a PFO may allow a completely fluoroless well tolerated and effective atrial fibrillation ablation. Probing the fossa ovalis looking for the PFO during the procedure is desirable, as it is not time-consuming and can potentially be done in every patient undergoing atrial fibrillation ablation.
2020
21
4
292
298
ablation; atrial fibrillation; fluoroscopy; patent foramen ovale; X-ray
Scaglione M.; Ebrille E.; Caponi D.; Battaglia A.; Di Donna P.; Anselmino M.; Peyracchia M.; Mazzucchi P.; Cerrato N.; Ferraris F.; Castagno D.; Lambe...espandi
File in questo prodotto:
File Dimensione Formato  
Post print.pdf

Open Access dal 02/05/2021

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.19 MB
Formato Adobe PDF
1.19 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1737222
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact