Background Excimer laser trabeculostomy (ELT) is a microinvasive glaucoma surgery (MIGS) that creates multiple laser channels through the trabecular meshwork using a cold laser system, which minimizes tissue fibrosis and aids in bypassing the main area of resistance to aqueous outflow. The purpose of this review is to evaluate the current body of evidence surrounding ELT in terms of efficacy and review the safety profile of the procedure. Main text Studies screened had to show clear inclusion and exclusion criteria as well as well-defined outcome measures. PubMed, MEDLINE, EMBASE and the Cochrane Controlled Trial Database were searched. Preferred Reporting Items of Systematic Reviews (PRISMA) guidelines were used to assess for study quality and for any bias. Sixty-four articles were initially identified with 18 meeting preliminary screening criteria. Ultimately, 8 studies met inclusion criteria and 2 additional non-referenced publications were also included: 1 randomized control trial, 4 prospective case series and 5 retrospective studies. Overall studies showed moderate intraocular pressure (IOP) lowering of between 20% and 40% from baseline without medication washout and mostly a decrease in glaucoma medications with few complications. Conclusion Current literature shows a significant IOP-lowering effect of ELT with a favorable safety-profile in standalone cases or combined with cataract surgery. Limitations to these studies are the lack of controls and washout IOP. Overall, ELT is an attractive MIGS option that does not require any residual device remaining in the angle.
Current review of Excimer laser Trabeculostomy
Fea, Antonio;Marolo, Paola;
2020-01-01
Abstract
Background Excimer laser trabeculostomy (ELT) is a microinvasive glaucoma surgery (MIGS) that creates multiple laser channels through the trabecular meshwork using a cold laser system, which minimizes tissue fibrosis and aids in bypassing the main area of resistance to aqueous outflow. The purpose of this review is to evaluate the current body of evidence surrounding ELT in terms of efficacy and review the safety profile of the procedure. Main text Studies screened had to show clear inclusion and exclusion criteria as well as well-defined outcome measures. PubMed, MEDLINE, EMBASE and the Cochrane Controlled Trial Database were searched. Preferred Reporting Items of Systematic Reviews (PRISMA) guidelines were used to assess for study quality and for any bias. Sixty-four articles were initially identified with 18 meeting preliminary screening criteria. Ultimately, 8 studies met inclusion criteria and 2 additional non-referenced publications were also included: 1 randomized control trial, 4 prospective case series and 5 retrospective studies. Overall studies showed moderate intraocular pressure (IOP) lowering of between 20% and 40% from baseline without medication washout and mostly a decrease in glaucoma medications with few complications. Conclusion Current literature shows a significant IOP-lowering effect of ELT with a favorable safety-profile in standalone cases or combined with cataract surgery. Limitations to these studies are the lack of controls and washout IOP. Overall, ELT is an attractive MIGS option that does not require any residual device remaining in the angle.File | Dimensione | Formato | |
---|---|---|---|
8r.pdf
Accesso aperto
Descrizione: eye and vision 2020
Tipo di file:
PDF EDITORIALE
Dimensione
666.44 kB
Formato
Adobe PDF
|
666.44 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.