Introduction: To evaluate the impact of short cementless stem on several clinical and radiographic outcomes, with particular focus on blood loss, in comparison with conventional cementless stem in total hip arthroplasty (THA). Materials and methods: Patients undergoing THA with GTS short stem or CLS conventional stem were included. Clinical data were retrospectively collected including preoperative and postoperative day 1 value for haemoglobin (HB); rate of postoperative blood transfusions; intraoperative bone infractions; stem alignment; 5-year follow-up Harris Hip Score (HHS) and rate of stem revision at 5 years of follow-up of the short and conventional cementless stem. Results: GTS and CLS stem group included 374 and 321 patients, respectively. The mean difference between the preoperative and postoperative day 1 HB value was 3.98 g/dL (SD 1.12) and 3.67 g/dL (SD 1.19) in the GTS and CLS group, respectively, which correspond to a crude effect (β) of 0.32 (95% CI 0.15; 0.49) and adjusted effect of 0.11 (95% CI − 0.08; 0.3). GTS group reported a significantly higher number of patients with excellent results in terms of HHS (p = 0.001). The rate of intraoperative bone infractions was 1.6% and 0.3% in the GTS and CLS group, respectively (p = 0.013). At radiographic assessment, the rate of varus position of the stem was 14% in the GTS group and 6% in the CLS group (p < 0.0001). The rate of stem revision at 5 years of follow-up was 0.8% and 0.4% in the GTS and CLS group, respectively (p = 0.63). Conclusions: GTS short stem was not associated with a clinically significant lower blood loss in the immediately postoperative period. Unadjusted exploratory analyses show that GTS stem provides the same results of CLS stem in terms of HHS and rate of stem revision at 5 years of follow-up.

Blood loss in primary total hip arthroplasty with a short versus conventional cementless stem: a retrospective cohort study

Pizzi C.;
2020-01-01

Abstract

Introduction: To evaluate the impact of short cementless stem on several clinical and radiographic outcomes, with particular focus on blood loss, in comparison with conventional cementless stem in total hip arthroplasty (THA). Materials and methods: Patients undergoing THA with GTS short stem or CLS conventional stem were included. Clinical data were retrospectively collected including preoperative and postoperative day 1 value for haemoglobin (HB); rate of postoperative blood transfusions; intraoperative bone infractions; stem alignment; 5-year follow-up Harris Hip Score (HHS) and rate of stem revision at 5 years of follow-up of the short and conventional cementless stem. Results: GTS and CLS stem group included 374 and 321 patients, respectively. The mean difference between the preoperative and postoperative day 1 HB value was 3.98 g/dL (SD 1.12) and 3.67 g/dL (SD 1.19) in the GTS and CLS group, respectively, which correspond to a crude effect (β) of 0.32 (95% CI 0.15; 0.49) and adjusted effect of 0.11 (95% CI − 0.08; 0.3). GTS group reported a significantly higher number of patients with excellent results in terms of HHS (p = 0.001). The rate of intraoperative bone infractions was 1.6% and 0.3% in the GTS and CLS group, respectively (p = 0.013). At radiographic assessment, the rate of varus position of the stem was 14% in the GTS group and 6% in the CLS group (p < 0.0001). The rate of stem revision at 5 years of follow-up was 0.8% and 0.4% in the GTS and CLS group, respectively (p = 0.63). Conclusions: GTS short stem was not associated with a clinically significant lower blood loss in the immediately postoperative period. Unadjusted exploratory analyses show that GTS stem provides the same results of CLS stem in terms of HHS and rate of stem revision at 5 years of follow-up.
2020
140
10
1551
1558
Blood loss; Conventional stem; Short stem; Total hip arthroplasty; Uncemented
Loppini M.; Della Rocca A.; Ferrentino D.; Pizzi C.; Grappiolo G.
File in questo prodotto:
File Dimensione Formato  
32743702.pdf

Open Access dal 03/08/2021

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 163.74 kB
Formato Adobe PDF
163.74 kB Adobe PDF Visualizza/Apri
32743702_pizzi.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 766.06 kB
Formato Adobe PDF
766.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1757854
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact