Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery. Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy. Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm. Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments. Level of evidence: 4 Laryngoscope, 2021.

Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients

Zavattero E.;Copelli C.;Borbon C.;Ramieri G.;
2021-01-01

Abstract

Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery. Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy. Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm. Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments. Level of evidence: 4 Laryngoscope, 2021.
2021
131
7
E2169
E2175
accuracy of reconstruction; CAD/CAM; fibula flap; mandibular reconstruction; reconstruction surgery
Zavattero E.; Bolzoni A.; Dell'Aversana G.; Sant'Agata M.; Massarelli O.; Ferri A.; Della Monaca M.; Copelli C.; Gessaroli M.; Valsecchi S.; Borbon C.; Beltramini G.A.; Ramieri G.; Valentini V.; Tartaro G.P.; Cocchi R.; Varazzani A.; Califano L.; Baj A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1770619
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact