Background: The aim of this study was to evaluate the macro-and micro-structure and the chemical composition of the surface of 5 different commercially available dental implants. Roughness values were also calculated. Materials and Methods: 1 zirconia implant (NobelPearl of Nobel Biocare) and 4 titanium implants, Syra (Sweden&Martina), Prama (Sweden&Martina), T3 (Biomet 3i), and Shard (Mech&Human), were analyzed through SEM-EDX analysis and quantitative evaluation of surface roughness (1 sample), and XPS chemical analysis (1 sample). Surface roughness was quantitatively assessed using the stereo-SEM method (SSEM). The following area roughness parameters were calculated, according to ISO25178: Sa, Sz, and Sdr. Results: From the SEM observations, all the implants analyzed presented modern well-developed micro-structures as the result of the specific process of double acid etching alone or combined with other additional treatments. Roughness values were generally greater at the level of the implant body and lower at the collar. The chemical characterization of the implant surfaces exhibited excellent results for all of the implants and indicated good care in the production processes. Conclusions: All the samples were well-conceived in terms of topography and surface roughness, and clean in terms of chemical residues.

Morphological and chemical characterization of titanium and zirconia dental implants with different macro-and micro-structure

Pera F.;
2020-01-01

Abstract

Background: The aim of this study was to evaluate the macro-and micro-structure and the chemical composition of the surface of 5 different commercially available dental implants. Roughness values were also calculated. Materials and Methods: 1 zirconia implant (NobelPearl of Nobel Biocare) and 4 titanium implants, Syra (Sweden&Martina), Prama (Sweden&Martina), T3 (Biomet 3i), and Shard (Mech&Human), were analyzed through SEM-EDX analysis and quantitative evaluation of surface roughness (1 sample), and XPS chemical analysis (1 sample). Surface roughness was quantitatively assessed using the stereo-SEM method (SSEM). The following area roughness parameters were calculated, according to ISO25178: Sa, Sz, and Sdr. Results: From the SEM observations, all the implants analyzed presented modern well-developed micro-structures as the result of the specific process of double acid etching alone or combined with other additional treatments. Roughness values were generally greater at the level of the implant body and lower at the collar. The chemical characterization of the implant surfaces exhibited excellent results for all of the implants and indicated good care in the production processes. Conclusions: All the samples were well-conceived in terms of topography and surface roughness, and clean in terms of chemical residues.
2020
10
21
1
15
Dental implants; Roughness; Titanium; XPS; Zirconia
Menini M.; Pera F.; Bagnasco F.; Delucchi F.; Morganti E.; Canullo L.; Pesce P.
File in questo prodotto:
File Dimensione Formato  
app10217520.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1850026
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact