Objectives: : Quantification of plasma hepatitis D virus (HDV) RNA is the essential tool for patient management under antiviral therapy. The aim of this European multicenter study was to improve the comparability of quantitative results reported by different laboratories using the CE/IVD-labeled RoboGene HDV RNA Quantification Kit 2.0 (Roboscreen GmbH) with different manual or automated nucleic acid extraction protocols/platforms and amplification/detection devices. Methods: : For harmonization of HDV RNA concentrations obtained by different protocols, correction factors (CF) were determined using the 1st WHO International Standard for HDV RNA. The limit of detection (LOD) and accuracy were determined for each protocol by using reference material. Furthermore, clinical samples were analyzed and results compared. Results: : The CF ranged from 20 to 1,870 depending on the protocol used. The LOD was found between 4 and 450 IU/ml. When accuracy was tested, external quality control (EQC) samples containing low HDV RNA concentrations were not detected by those protocols with higher LODs. For EQC samples, the maximum standard deviation of HDV RNA concentrations was found to be 0.53 log10 IU/ml, for clinical samples 0.87 log10 IU/mL. Conclusion: : To ensure reliability in quantification of HDV RNA, any modification of the extraction and amplification/detection protocol validated by the manufacturer requires revalidation. With the 1st WHO International Standard for HDV RNA, the CF could easily be calculated leading to harmonization of quantitative results. This warrants both accurate monitoring of response to existing anti-HDV treatment and comparability of study results investigating novel anti-HDV drugs.

Reliable quantification of plasma HDV RNA is of paramount importance for treatment monitoring: A European multicenter study

Olivero A.;
2021-01-01

Abstract

Objectives: : Quantification of plasma hepatitis D virus (HDV) RNA is the essential tool for patient management under antiviral therapy. The aim of this European multicenter study was to improve the comparability of quantitative results reported by different laboratories using the CE/IVD-labeled RoboGene HDV RNA Quantification Kit 2.0 (Roboscreen GmbH) with different manual or automated nucleic acid extraction protocols/platforms and amplification/detection devices. Methods: : For harmonization of HDV RNA concentrations obtained by different protocols, correction factors (CF) were determined using the 1st WHO International Standard for HDV RNA. The limit of detection (LOD) and accuracy were determined for each protocol by using reference material. Furthermore, clinical samples were analyzed and results compared. Results: : The CF ranged from 20 to 1,870 depending on the protocol used. The LOD was found between 4 and 450 IU/ml. When accuracy was tested, external quality control (EQC) samples containing low HDV RNA concentrations were not detected by those protocols with higher LODs. For EQC samples, the maximum standard deviation of HDV RNA concentrations was found to be 0.53 log10 IU/ml, for clinical samples 0.87 log10 IU/mL. Conclusion: : To ensure reliability in quantification of HDV RNA, any modification of the extraction and amplification/detection protocol validated by the manufacturer requires revalidation. With the 1st WHO International Standard for HDV RNA, the CF could easily be calculated leading to harmonization of quantitative results. This warrants both accurate monitoring of response to existing anti-HDV treatment and comparability of study results investigating novel anti-HDV drugs.
2021
142
104932
1
6
1st WHO International Standard for HDV RNA; Extraction platforms; Hepatitis D virus (HDV); IU/mL; Quantitative real-time pcr; Hepatitis Delta Virus; Humans; RNA, Viral; Reproducibility of Results; Viral Load; Hepatitis D; Pharmaceutical Preparations
Stelzl E.; Ciesek S.; Cornberg M.; Maasoumy B.; Heim A.; Chudy M.; Olivero A.; Miklau F.N.; Nickel A.; Reinhardt A.; Dietzsch M.; Kessler H.H....espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1855474
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 21
social impact