Aims Despite the general adoption of a 3-month blanking period (BP), increasing scientific evidence suggests an association between early recurrences of atrial tachyarrhythmias (ERAT) and failure of atrial fibrillation catheter ablation (AFCA). The aim of the present study was to perform a diagnostic meta-analysis to derive the ideal BP cut-off following AFCA.Methods and results PubMed/MEDLINE databases were screened for articles reporting late recurrences of atrial tachyarrhythmias (LRAT) in AFCA patients experiencing an ERAT (with at least one time cut-off). Seventeen studies were finally included in the analysis, encompassing 5837 AF patients experiencing ERAT after AFCA. A random-effect meta-analysis of diagnostic test accuracy studies with multiple cut-offs was performed. The day at which the ERAT occurred was considered the diagnostic 'test', whereas the different time cut-offs reported in the singular studies were treated as cut-offs of interest in the meta-analysis. Overall, a 27.7 day (95% confidence interval: 10.4-45.1 days) cut-off was identified as the optimal BP duration [area under the summary receiver operating characteristic (AUC-SROC) curve: 0.66, 95% CI: 0.56-0.75]. Specificity (95% CI: 63-85%) and positive predictive value were 76%. At subgroup analysis, the optimal BP cut-off was 39.0 days (95% CI: 26.8-51.2 days, AUC-SROC: 0.63) following radiofrequency AFCA and 30.1 days (95% CI: 0-63.4 days, AUC-SROC: 0.76) after cryoballoon ablation.Conclusion The present meta-analysis indicates that a 4-week BP represents the optimal cut-off following AFCA. Altogether, these meta-analytic insights support the need of a revision of the actual 3-month BP duration.[GRAPHICS]

Evidence-based insights on ideal blanking period duration following atrial fibrillation catheter ablation

Saglietto, Andrea;Ballatore, Andrea;Gaita, Fiorenzo;De Ferrari, Gaetano Maria
;
Anselmino, Matteo
Last
2022-01-01

Abstract

Aims Despite the general adoption of a 3-month blanking period (BP), increasing scientific evidence suggests an association between early recurrences of atrial tachyarrhythmias (ERAT) and failure of atrial fibrillation catheter ablation (AFCA). The aim of the present study was to perform a diagnostic meta-analysis to derive the ideal BP cut-off following AFCA.Methods and results PubMed/MEDLINE databases were screened for articles reporting late recurrences of atrial tachyarrhythmias (LRAT) in AFCA patients experiencing an ERAT (with at least one time cut-off). Seventeen studies were finally included in the analysis, encompassing 5837 AF patients experiencing ERAT after AFCA. A random-effect meta-analysis of diagnostic test accuracy studies with multiple cut-offs was performed. The day at which the ERAT occurred was considered the diagnostic 'test', whereas the different time cut-offs reported in the singular studies were treated as cut-offs of interest in the meta-analysis. Overall, a 27.7 day (95% confidence interval: 10.4-45.1 days) cut-off was identified as the optimal BP duration [area under the summary receiver operating characteristic (AUC-SROC) curve: 0.66, 95% CI: 0.56-0.75]. Specificity (95% CI: 63-85%) and positive predictive value were 76%. At subgroup analysis, the optimal BP cut-off was 39.0 days (95% CI: 26.8-51.2 days, AUC-SROC: 0.63) following radiofrequency AFCA and 30.1 days (95% CI: 0-63.4 days, AUC-SROC: 0.76) after cryoballoon ablation.Conclusion The present meta-analysis indicates that a 4-week BP represents the optimal cut-off following AFCA. Altogether, these meta-analytic insights support the need of a revision of the actual 3-month BP duration.[GRAPHICS]
2022
24
12
1899
1908
Atrial fibrillation; Blanking period; Catheter ablation; Early recurrence
Saglietto, Andrea; Ballatore, Andrea; Xhakupi, Henri; Rubat Baleuri, Federico; Magnano, Massimo; Gaita, Fiorenzo; De Ferrari, Gaetano Maria; Anselmino, Matteo
File in questo prodotto:
File Dimensione Formato  
Manuscript_Blankin_Europace_Revision 30032022.docx

Open Access dal 02/09/2023

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.08 MB
Formato Microsoft Word XML
1.08 MB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1879262
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 9