Objectives: The incidence of outcomes in trials comparing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) is expected to be different in the short and long term. We planned a meta-analysis of reconstructed time-to-event data from trials comparing TAVI and SAVR to evaluate their time-varying effects on outcomes. Methods: We performed a systematic review of the literature from January 2007 through September 2021 on Medline, Embase, the Cochrane Central Register of Controlled Trials and specialistic websites, including randomized trials with allocation to TAVI or SAVR that reported at least 1-year follow-up and that graphed Kaplan-Meier curves of end points. The comparisons were done with grouped frailty Cox models in a landmark framework and fully parametric models. Results: Seven trials were included (7770 participants). TAVI showed a lower incidence of the composite of death or stroke in the first 6 months [risk-stratified hazard ratio (HR) 0.66, 95% confidence interval (CI) 0.56-0.77, P-value <0.001], with an HR reversal after 24 months favouring SAVR (risk-stratified HR 1.25; 95% CI 1.08-1.46; P-value 0.003). These outcomes were confirmed for all-cause death (risk-stratified HR after 24 months 1.18; 95% CI 1.03-1.35; P-value 0.01). TAVI was also associated with an increased incidence of rehospitalization after 6 months (risk-stratified HR 1.42; 95% CI 1.06-1.91; P-value 0.018) that got worse after 24 months (risk-stratified HR 1.67; 95% CI 1.24-2.24; P-value <0.001). Conclusions: Although it could appear that there is no difference between TAVI and SAVR in the 5-year cumulative results, TAVI shows a strong protective effect in the short term that runs out after 1 year. TAVI becomes a risk factor for all-cause mortality and the composite end point after 24 months and for rehospitalization after 6 months.

Five-year outcomes in trials comparing transcatheter aortic valve implantation versus surgical aortic valve replacement: a pooled meta-analysis of reconstructed time-to-event data

Martin, Barbara;Rinaldi, Mauro;
2022-01-01

Abstract

Objectives: The incidence of outcomes in trials comparing transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) is expected to be different in the short and long term. We planned a meta-analysis of reconstructed time-to-event data from trials comparing TAVI and SAVR to evaluate their time-varying effects on outcomes. Methods: We performed a systematic review of the literature from January 2007 through September 2021 on Medline, Embase, the Cochrane Central Register of Controlled Trials and specialistic websites, including randomized trials with allocation to TAVI or SAVR that reported at least 1-year follow-up and that graphed Kaplan-Meier curves of end points. The comparisons were done with grouped frailty Cox models in a landmark framework and fully parametric models. Results: Seven trials were included (7770 participants). TAVI showed a lower incidence of the composite of death or stroke in the first 6 months [risk-stratified hazard ratio (HR) 0.66, 95% confidence interval (CI) 0.56-0.77, P-value <0.001], with an HR reversal after 24 months favouring SAVR (risk-stratified HR 1.25; 95% CI 1.08-1.46; P-value 0.003). These outcomes were confirmed for all-cause death (risk-stratified HR after 24 months 1.18; 95% CI 1.03-1.35; P-value 0.01). TAVI was also associated with an increased incidence of rehospitalization after 6 months (risk-stratified HR 1.42; 95% CI 1.06-1.91; P-value 0.018) that got worse after 24 months (risk-stratified HR 1.67; 95% CI 1.24-2.24; P-value <0.001). Conclusions: Although it could appear that there is no difference between TAVI and SAVR in the 5-year cumulative results, TAVI shows a strong protective effect in the short term that runs out after 1 year. TAVI becomes a risk factor for all-cause mortality and the composite end point after 24 months and for rehospitalization after 6 months.
2022
61
5
977
987
https://academic.oup.com/ejcts/article/61/5/977/6464130?login=true
Aortic valve stenosis; Follow-up; Surgical aortic valve replacement; Transcatheter aortic valve replacement
Barili, Fabio; Freemantle, Nicholas; Musumeci, Francesco; Martin, Barbara; Anselmi, Amedeo; Rinaldi, Mauro; Kaul, Sanjay; Rodriguez-Roda, Jorge; Di Mauro, Michele; Folliguet, Thierry; Verhoye, Jean-Philippe; Sousa-Uva, Miguel; Parolari, Alessandro
File in questo prodotto:
File Dimensione Formato  
European Journal of Cardio-Thoracic Surgery 2022.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.27 MB
Formato Adobe PDF
1.27 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1879604
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 15
social impact