In the investigation of gunshot deaths, Bloodstains Pattern Analysis (BPA) and, in particular, backspatter patterns found on the body of the suspect/victim and on the surfaces close to the entrance wound of the bullet can provide investigators with important indications on the dynamics of the events. Backspatter patterns have, however, morphological characteristics common to other bloodstains of different origin, so, in order to positively identify them, a possible solution is represented by their sampling, using an aluminum stub for electron microscopy, for the detection of gunshot residues (GSR) present. The latter, however, if present below the small blood crusts, could be difficult to detect during analysis by Scanning Electron Microscopy/Energy Dispersive X-ray microanalysis (SEM/EDX). In this preliminary study we propose the treatment of the stub surface with a solution based on sodium hypochlorite and calcium chloride, in order to remove/reduce the blood crusts present on the stub surface.

A preliminary study on the treatment of human blood soiled stubs, in presence of GSR particles

Marco Pazzi;Grazia Mattutino
2022-01-01

Abstract

In the investigation of gunshot deaths, Bloodstains Pattern Analysis (BPA) and, in particular, backspatter patterns found on the body of the suspect/victim and on the surfaces close to the entrance wound of the bullet can provide investigators with important indications on the dynamics of the events. Backspatter patterns have, however, morphological characteristics common to other bloodstains of different origin, so, in order to positively identify them, a possible solution is represented by their sampling, using an aluminum stub for electron microscopy, for the detection of gunshot residues (GSR) present. The latter, however, if present below the small blood crusts, could be difficult to detect during analysis by Scanning Electron Microscopy/Energy Dispersive X-ray microanalysis (SEM/EDX). In this preliminary study we propose the treatment of the stub surface with a solution based on sodium hypochlorite and calcium chloride, in order to remove/reduce the blood crusts present on the stub surface.
2022
335
2
1
5
https://www.sciencedirect.com/science/article/abs/pii/S0379073822001402
Bloodstain pattern analysis, Backspatter pattern, Gunshot residues, Scanning electron microscopy, Energy dispersive X-ray spectroscopy
Gabriele Rotter, Marco Pazzi, Grazia Mattutino
File in questo prodotto:
File Dimensione Formato  
Rotter-Pazzi-Mattutino, FSI 2022.pdf

Accesso riservato

Tipo di file: PREPRINT (PRIMA BOZZA)
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1879790
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact